NX-420
Receiver Section
Item
Panel tuning mode
1. AF level
[Panel test mode]
setting
1) CH-Sig: 1-1
SSG output:
–47dBm (1mV)
(MOD: 1kHz/±1.5kHz)
Wide 5k/Wide 4k/
Narrow: Narrow
Beat Shift: Uncheck
Compander: Uncheck
2. RSSI
1) Adj item: [RRSS]
reference
Adjust: [
*5
2) Adj item: [R.RSS_]
[R.R.S.S_]
[Analog
[R.R.S.S._.]
Narrow]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [RRSS]
Wide 4k]
Adjust: [
.
2) Adj item: [R.RSS_]
[R.R.S.S_]
[R.R.S.S._.]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±2.4kHz)
[Analog
1) Adj item: [RRSS]
Wide 5k]
Adjust: [
.
2) Adj item: [R.RSS_]
[R.R.S.S_]
[R.R.S.S._.]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±3kHz)
[NXDN
1) Adj item: [RRSS]
Verry
Adjust: [
Narrow]
2) Adj item: [R.RSS_]
[R.R.S.S_]
[R.R.S.S._.]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±1.5kHz)
*5: Because RSSI Reference (NXDN Narrow) is adjusted by adjusting RSSI Reference (Analog Narrow), it is not necessary to adjust RSSI Reference
(NXDN Narrow).
50
ADJUSTMENT
Condition
PC test mode
equipment
1) Test Channel
SSG
Channel: 1
DVM
Test Signaling
AF VM
Mode: Analog
Dummy
Signaling: 1
load
Wide 5k/Wide 4k/
Narrow: Narrow
Beat Shift: Uncheck
Compander: Uncheck
SSG output:
–47dBm (1mV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [RSSI
SSG
.]
Reference (Analog
Narrow)]
2) Adj item: [Low],
[Center], [High]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±1.5kHz)
1) Adj item: [RSSI
.]
Reference (Analog
Wide 4k)]
2) Adj item: [Low],
[Center], [High]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±2.4kHz)
1) Adj item: [RSSI
.
.]
Reference (Analog
Wide 5k)]
2) Adj item: [Low],
[Center], [High]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±3kHz)
1) Adj item: [RSSI Ref-
]
erence (NXDN Very
Narrow)]
2) Adj item: [Low],
[Center],[High]
SSG output: 12dB
SINAD level –3dB
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Unit
Terminal
Unit
Panel ANT
Panel Volume
SP/MIC
connector
Panel ANT
SP/MIC
connector
Adjustment
Specifi cations /
Parts
Method
Turn the Volume
0.63V±0.1V
knob
Knob to obtain
0.63V AF output.
[Panel tuning mode]
After input signal
from SSG, press
[
] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Adjust with the
analog signal.
Remarks

Hide quick links: