Kenwood NX-420 K Service Manual page 45

800mhz digital transceiver
Table of Contents

Advertisement

Item
Panel tuning mode
Maximum
1) Adj item: [ADEV]
Deviation
Adjust: [
.
(Analog)
2) Adj item: [A.DEV_]
*3
[A.D.E.V._.]
[A.DEV_]
(TA)
[A.D.E.V._.]
[Wide 5k]
(TA)
Adjust: [
.
.
.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
*3: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 49.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
6. QT
1) Adj item: [QT]
Deviation
Adjust: [
*4
2) Adj item: [Q.T._._._.]
[Q.T._._._.](TA)
[Narrow]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
[Wide 4k]
1) Adj item: [QT]
Adjust: [
.
2) Adj item: [Q.T._._._.]
[Q.T._._._.](TA)
PTT: ON
Press [
] key to
store the adjust-
ment value.
[Wide 5k]
1) Adj item: [QT]
Adjust: [
.
2) Adj item: [Q.T._._._.]
[Q.T._._._.](TA)
PTT: ON
Press [
] key to
store the adjust-
ment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
.
.]
Deviation (Analog
meter
Wide 5k)]
Oscilloscope
2) Adj item: [Low],
[High],[Low(TA)],
[High(TA)]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [QT
Deviation
.]
Deviation (Analog
meter
Narrow)]
Oscilloscope
2) Adj item: [Hight],
[Hight](TA)
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] button
to store the adjust-
ment value.
1) Adj item: [QT Devia-
.]
tion (Analog Wide
4k)]
2) Adj item: [Hight],
[Hight](TA)
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] button
to store the adjust-
ment value.
1) Adj item: [QT Devia-
.
.]
tion (Analog Wide
5k)]
2) Adj item: [Hight],
[Hight](TA)
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] button
to store the adjust-
ment value.
Measurement
Test-
Unit
Terminal
Unit
Panel ANT
Panel [Panel
Panel ANT
Panel [Panel
NX-420
Adjustment
Specifi cations /
Parts
Method
4200Hz
4150~4250Hz
tuning
Write the value as
mode]
followings.
[PC test mode]
Selector
513 (Reference
Press [Apply All]
value)
button to store the
[PC test
adjustment value
mode]
after all adjustment
[ ],[ ]
points have been
adjusted.
Write the value as
0.35kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
0.60kHz±0.05kHz
0.75kHz±0.05kHz
Remarks
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-420 seriesNx-420 k3

Table of Contents