  • Page 1 Original instructions Dynamic Series User manual Description, warnings and instructions LIDYNE00-07...
  • Page 3 No part of the documentation may be reproduced, in any form or by any means, without written permission of Autec (including recording and photocopying). If documentation is lost or damaged, ask Autec for a copy. Please specify the serial number of the related radio remote control.
  • Page 4 …highly probable. … critical. physical damage). … critical (death or … probable. … critical. physical damage). … moderate (non-severe … probable. … moderate. physical damage). This symbol is also used, and it identifies texts to be read carefully. LIDYNE00-07 AUTEC...
  • Page 5: Table Of Contents

    DynamIc SerIeS Part a: Description, warnings and instructions InDex radio remote control description ................ 7 1.1 How the radio remote control works ..............7 1.2 Technical Data ....................7 1.3 Applications ..................... 8 1.4 Radio link ......................8 1.5 Classification of commands ................9 1.6 Safety functions ....................
  • Page 6 Troubleshooting ....................33 7.1 Radio remote controls with Data Feedback function ........33 7.2 Radio remote controls with wire control ............33 7.3 Solutions in case of malfunction ..............33 LIDYNE00-07 AUTEC...
  • Page 7: Radio Remote Control Description

    ....................PL d / SIL 2 (2-wire wiring) Protection against unintended movements from the standstill position (UMFS) PL d / SIL 2 Passive stop cut-in time is set by the machine manufacturer (see technical data sheet). AUTEC - Dynamic Series LIDYNE00-07...
  • Page 8: Applications

    This is an essential requirement to ensure safety for the radio remote controlled machine. The two units use messages coded through an address that is unique (produced by Autec only once), univocal (specific for each radio remote control) and cannot be reproduced. Each unit can only decode messages coming from the unit with the same address.
  • Page 9: Classification Of Commands

    Safety functions Autec radio remote controls are equipped with some functions that provide high safety levels, in order to safeguard the safety of people and property.
  • Page 10: Identifying The Radio Remote Control

    This is the only reference to be used both for maintenance operations and for declarations to competent bodies. Plates on the units must not be: - removed from their position (removal voids the guarantee) - altered or damaged (contact Autec for replacement) LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 11: Risk Assessment

    The machine manufacturer and/or the person who decides upon radio remote control installation and use is responsible for this risk assessment. autec cannot be held responsible if this assessment has not been carried out correctly or is incomplete. If required by the risk assessment, implement protection measures to prevent, reduce and report potential hazardous situations.
  • Page 12: Staff Training

    "machine+radio remote control" system is used. autec cannot be held responsible if the radio remote control is used in unlawful working conditions.
  • Page 13: Warnings For Use

    (symbols used are defined by the machine manufacturer and/or installer depending on the machine's operation and functions). During normal operation Pay attention to the entire work area. Immediately press the STOP pushbutton when a hazardous situation occurs. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 14: After Using The Radio Remote Control

    If an "Key ID 0-1" is in the transmitting unit, always store it in a safe place each time it is removed. If this key is lost, the radio remote control cannot work, since the transmitting unit needs the address stored in the key to work with its receiving unit. LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 15: Radio Remote Control Life Cycle

    Please contact the machine manufacturer or the person who decided upon the installation of the radio remote control for instructions and warnings regarding the installation. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 16: Use

    All fine-tuning, checking and maintenance actions carried out on the radio remote control shall be verified and recorded by the person in charge of carrying out maintenance on the machine. LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 17 - check that the three plates on the transmitting unit are readable and intact - make sure that the mechanical operation of the STOP pushbutton is correct - check structural integrity of the transmitting unit. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 18 - follow the instructions to detect possible malfunctions and their origins. any fault should be repaired by authorised personnel only (contact the support service of the machine's manufacturer), using original autec spare parts only. The following radio remote control data must be reported in order to make interventions...
  • Page 19 5x10 5x10 5x10 3x10 6x10 5x10 AUTEC - Dynamic Series LIDYNE00-07...
  • Page 20 - make sure that the surface of electrical connections is covered with a layer of grease and add it if necessary - contact the support service of the machine's manufacturer if evident oxidation is detected. LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 21: Machine Maintenance

    In the event of necessary maintenance on the machine (i.e. soldering), disconnect all the electrical connections of the receiving unit. Disposal When disposing of a radio remote control, give it to the waste separate collecting services in the user's country. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 22: General Operating Instructions

    (symbols used are defined by the machine manufacturer according to the functions of the machine). The transmitting unit can have some specific commands (see paragraph 6.6). LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 23: Data Feedback Function

    If this may lead to a dangerous situation, press and then unlock the STOP pushbutton. Only then, press the STarT pushbutton. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 24: Transmitting Unit Automatic Switch Off

    The transmitting unit indicates if it has been used for eight hours non-stop (the red LED blinks and an acoustic signal sounds). The transmitting unit automatically switches off after 3.5 minutes from the beginning of the signal. LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 25: Switching Off The Transmitting Unit

    The receiving unit shall be switched off each time the radio remote control is not used to control the machine. Remove power from the unit to switch it off. When the radio remote control is installed on machines on board vehicles, switch off the receiving unit while the vehicle is travelling. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 26: Operation

    Operation Operation Battery The Dynamic series' transmitting units can only be powered by autec rechargeable batteries. See the battery charger manual enclosed in the packaging with the battery charger for any warnings and instructions regarding the batteries. 6.1.1 Battery insertion Push the battery towards the contacts on the transmitting unit (1) and insert it inside the housing (2).
  • Page 27: Power Keyswitch

    2. rotate the power keyswitch clockwise. 6.3.4 power keyswitch removal Perform the following operations to remove the power keyswitch: 3. rotate the power keyswitch anticlockwise 4. pull the power keyswitch to remove it from the corresponding housing. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 28: Start Pushbutton

    UP UNIT" transmitting unit. STarT pushbutton The START pushbutton is used to: - start up the radio remote control (see paragraphs 5.1, 5.4 and 5.5) - activate the horn when the radio remote control is started. LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 29: Stop Pushbutton

    This switch increases (rpm +) or decreases (rpm -) the engine revolutions of the remote controlled machine. Symbol meaning This symbol indicates the increase of the machine's engine revolutions. This symbol indicates the decrease of the machine's engine revolutions. AUTEC - Dynamic Series LIDYNE00-07...
  • Page 30 This symbol indicates a reduction in the machine's speed (the reduction is set by the manufacturer). This symbol, if present, indicates a further reduction in the machine's speed (the reduction is set by the manufacturer). LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 31: Low Power Function

    - making it easier to work with several systems in the same working environment (i.e.: many working machines in the same working area) - extending the battery run-time. This function is established by the machine manufacturer (see technical data sheet). AUTEC - Dynamic Series LIDYNE00-07...
  • Page 32: Cable Control

    When you finish working with the wire control, disconnect the cable from the transmitting unit and from the machine, and protect the connectors with their caps. LIDYNE00-07 AUTEC - Dynamic Series...
  • Page 33: Troubleshooting

    Look up in “Part C” and/or in “Part D” of the manual to identify the radio remote control malfunction signalled by light signals on the units. If the problem persists after the suggested solution has been carried out, contact the support service of the machine manufacturer. AUTEC - Dynamic Series LIDYNE00-07...