1
Description ............................................................................................................ 2
2
Technical data ....................................................................................................... 3
3
Technical data sheet ............................................................................................. 3
4
Plates ..................................................................................................................... 4
5
Light signals .......................................................................................................... 4
5.1 POWER LED (green) ....................................................................................... 4
5.2 ALARM LED (red) ............................................................................................ 5
5.3 STATUS LED (blue) ......................................................................................... 5
5.4 LED RUN (green) e LED ERR (red) ................................................................. 5
5.5 SETUP LED (yellow) ........................................................................................ 5
6
malfunction signalled by the receiving unit ........................................................ 6
AUTEC
receiving unit Pcr
inDex
LIPCRE00-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dynamic Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AUTEC Dynamic Series

  • Page 1: Table Of Contents

    Original instructions Dynamic SerieS receiving unit Pcr inDex Description ......................2 Technical data ....................... 3 Technical data sheet ..................... 3 Plates ........................4 Light signals ......................4 5.1 POWER LED (green) ..................4 5.2 ALARM LED (red) .................... 5 5.3 STATUS LED (blue) ..................5 5.4 LED RUN (green) e LED ERR (red) ..............
  • Page 2: Description

    The receiving unit is interfaced with the machine through the outputs and their wiring and/or through a CAN network (of which it is a master node). The STOP (STP_1 and STP_2) and SAFETY (SAF_1 and SAF_2) outputs are some of the receiving unit's outputs. LIPCRE00-00 AUTEC - Dynamic Series...
  • Page 3: Technical Data

    A technical data sheet must always be kept toghether with this manual (always keep a copy of the technical data sheet when it is used for administrative purposes). The wiring of the receiving unit outputs must always reflect the wiring indicated in the technical data sheet. AUTEC - Dynamic Series LIPCRE00-00...
  • Page 4: Plates

    The POWer LeD... meaning …is off The receiving unit is not powered..is on The receiving unit is powered and radio link is missing. The receiving unit is powered and radio link has been … blinks established. LIPCRE00-00 AUTEC - Dynamic Series...
  • Page 5: Alarm Led (Red)

    RUN and ERR LED signals are configurable during the maschine installation: it is recommended to respect the guidelines of the CANopen® standard, CiA recommendation 303-3. SeTUP LeD (yellow) SETUP LED signals are configurable during the machine installation. AUTEC - Dynamic Series LIPCRE00-00...
  • Page 6: Malfunction Signalled By The Receiving Unit

    Make sure that the outputs of times. commands. direction commands are wired correctly. The receiving unit does not Contact the support service of The aLarm LeD is on. work correctly. the machine manufacturer. LIPCRE00-00 AUTEC - Dynamic Series...
  • Page 7 If this signal persists, contact and irregularly. unit. the support service of the machine manufacturer. Over-current in one of the Contact the support service of The STaTUS LeD is on. PWM analogue outputs. the machine manufacturer. AUTEC - Dynamic Series LIPCRE00-00...