Burner Data - Slant/Fin XL-2000 Installation And Operating Instructions Manual

Oil-fired water boilers/no. 2 oil
Table of Contents

Advertisement

XL-2000
BURNER DATA—CARLIN BURNERS FOR PACKAGED BOILERS ONLY
BOILER
CARLIN BURNER
MODEL
MODEL (2) (3)
XL-20
99-FRD
71399-00F-XL-20
XL-30
99-FRD
71399-00F-XL-30
XL-40
99-FRD
71399-00F-XL-40
XL-50
99-FRD
71399-00F-XL-50
NOTES:
(1) Single slotted air band for XL-20 and XL-30, double slotted air band for XL-40 and XL-50.
(2) See "PRECAUTIONS BEFORE STARTING OIL BURNERS" and "START-UP" on page 7 and burner figures on this page.
(3) All burner models shown are single stage.
NOZZLES
FIRING
ANGLE
RATE
AND
NO. 2 OIL
SIZE
TYPE
(GPH)
(GPH)
0.65
0.65
70° A
0.65
70° W DELAVAN
1.00
1.00
70° A
1.15
1.00
70° A
1.35
1.35
60° W DELAVAN
1.55
1.35
60° W DELAVAN
1.80
1.75
60° B
2.00
1.75
60° B
OIL PUMP
PRESSURE
APPROXIMATE
SETTING
HEAD SETTING
MFR.
(PSIG)
DELAVAN
100
100
DELAVAN
100
DELAVAN
130
100
130
DELAVAN
105
DELAVAN
130
"A"
APPROXIMATE
AIR BAND
OPENING %
NO.
(1)
0
50
0
50
2
80
3
90
4
50
4
65
4
20
5
40
11
SHUTTER
NON-
ADJUSTABLE
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open