Touch Area Boundary Fine-tuning
Step 1: Click on P1, use mouse to drag P1 to upper left corner. Align adjustable green zone with
projected white frame.
Step 2: Adjust P2 to P4 accordingly; adjustable green zone should completely overlaps the
projected white frame.
Step 3: Finally, check again if the green frame completely overlaps the projected white frame. If
not, fine-adjust again.
When the Touch Area is correctly located click to exit.
STEP 4: CALIBRATION
a) Select Auto Calibration
Note:
If the fail message pops up, follow below steps to trouble-shoot and do Auto Calibration again.
Close all software application
Reduce ambient light
Do not obstruct or shake lens during calibration
Check if projection image is clear. If not, adjust focus to sharpen the image
If the Auto Calibration fail message still pops up on screen, switch to Manual Calibration.