Output Ratings - Sevcon Gen4 Applications Reference Manual

Table of Contents

Advertisement

Output ratings

Input
Function
(Vdc)
24
Single traction size 2
24/36
Single traction size 4
Single traction size 6
Single traction size 2
36/48
Single traction size 4
Single traction size 6
Single traction size 2
72/80
Single traction size 4
Single traction size 6
Single traction size 4
96/110
*2 minute rating (lower ratings are possible for longer periods; see example in Figure 10)
** 1 hour minimum without forced-air cooling
Size 2 long-term rating achievable with finned heatsink approx 250mm x 180mm, 0.5°C/W
Size 4 long-term rating achievable with finned heatsink approx 330mm x 200mm, 0.3°C/W
Size 6 long-term rating achievable with finned heatsink approx 330mm x 280mm, 0.2°C/W
Figure 10 Output current available for various durations of sustained current
demand
4-4
Short term
Continuous
rating* (A rms)
rating** (A rms)
300
120
450
180
650
260
275
110
450
180
650
260
180
75
350
140
550
210
300
120