Technical data

TECHNICAL DATA
Dimensions:
Weight (CFT 013/014):
Weight (CFT 0361/0461):
Water connection:
Cold water connection:
for café cool (option)
Water filling capacity:
Beverage capacity:
Concentrate capacity:
Electrical data:
Electric connection:
Length of the power cable:
General installation requirements:
The dispenser is marked with the CE label. (Directive about electrical equipment of low voltage, directive about electromagnetic compatibility)
Subject to changes!
4
Height: 780 mm (30.7 in)
34.3 kg (75.5 lbs) (net weight), 50 kg (110 lbs) filled
29 kg (63.9 lbs) (net weight), 44 kg (97 lbs) filled
Drinking water line with stop valve. Connection to hot water supply via copper pipes only.
Supply system requirements:
Temperature:
max. 75 °C (167 °F)
Dynamic pressure:
min. 0.8 bar (11 psi) with 10l/min (2.64 US gal/min. / 2.20 UK gal/min.)
Static pressure:
max. 10 bar (140 psi)
Dynamic pressure:
min. 0.8 bar (11 psi) with 1.2 l/min (0.31 US gal/min. / 0.26 UK gal/min.)
Static pressure:
max. 7 bar (98 psi)
10 l (2.64 US gal / 2.20 UK gal) (pressureless boiler)
100 cups à 100 ml/hour (6.1 in
Coffee, tea, milk or packs containing lactiferous beverages with a contents of
2 l (0.53 US gal / 0.44 UK gal) each
See the rating plate for the electrical data.
The adjustments might be changed by a service technician.
1-phase operation Europe/Japan/Australia
3-phase operation Europe/Australia
1-phase operation USA
2-phase operation USA
Only by power cable and plug, otherwise a contact breaking device for all poles must be
installed. The dispenser is radioshielded acc. to EN 55014/VDE 0875,T14.
The connection must be earthed!
The installation of a fault current safety switch is recommended.
approx. 1.80m (5.9 ft)
Height:
Ambient temperature:
Min. distance to the wall:
The dispenser is protected against dripping water.
Width: 320 mm (12.60 in)
3
/hour) per kW heating capacity
max. 3.5KW at 230V~ / 2.7KW at 200V~
max. 8.1KW at 3N~ 400V
max. 1,8kW at 120V~
max. 2,4/3,1kW at 208/240V~/2,9/3,8kW at 208/240V~
max. 4,4/5,8kW at 208/240V~ / 6,8/8,9kW at 208/240V~
up to 2000 m (6562 ft)
5 °C - max. 32 °C (41°F - max. 90°F)
50 mm (1.997 in) (from backside of the machine)
Depth: 515 mm (20.28 in)
Series 03
05.01