4.2 Keypad Operation Process
4.2.1 Parameter Setting
Three levels of menu are as following
• Function code group (first-class)
• Function code (second-class)
• Setting parameter of function code (third-class)
In order to set up the electric automatic start function FD.07=11 as an example, the
modified parameter flow chart is as follows:
Stand By Status
(Frequency/HZ)
Display
0.00
Reading:
Button:
Run Status
(Frequency/HZ)
Display
0.00
Reading:
Button:
4.2.2 Fault Reset
After the controller has failed, the controller will display the relevant fault code
information. The conventional fault code (E002/3/4/5/6/7/8/9/10/11/12/18) can
automatically reset after 10s operation, and can also choose to reset the
STOP/RESET on the keyboard. If the conventional failure persists, the controller
will reset once every 10s. Special fault code (E001/13/14) requires the user through
the STOP/RESET key on the keyboard to reset the fault; the controller can continue
to run after the reset.
Run/stop key
First Class
F0
MENU
First Class
FD
MENU
S
Figure12
chematic Diagram of Function Parameters
Start to run the controller in keypad control mode
and In running status, use it to stop the controller.
:
First Class
Second Class
FD
FD.07
ENT
ENT
Second Class
Third Class
New Value
FD.10
11
ENT
MENU
- 27 -
Third Class
Value Now
10