PDS33 Series
2.4 PDS33 Solar Pump Controller Model Description
2.4.1 Model Description
Segment
Description
①
PDS series
②
Series ID
Rated Output
③
Voltage
④
Input Voltage
⑤
Motor Power Rating
Note 1: Supporting Alternating Current input, with voltage rating of 220VAC single phase connected
to terminal R&T.
Note 2: Supporting Alternating Current input, with voltage rating of 380VAC three phase connected to
terminal R, S and T.
2.4.2 PDS33 Solar Controller General Parameters
Surge Protection
Under voltage Protection
Open circuit Protection
Overheated Protection
RS485
GPRS
Ambient Temperature Range
Cooling Method
Ambient Humidity
Standard Warranty(month)
Certificates
PDS33 -
4T5R5
① ②
③④⑤
3: Series of 3rd generation.
3: Apply to three-phase induction motor
2: 220V three phase; 4: 380V three phase
S: 310VDC rating, MPPT range 280VDC~360VDC(Note 1)
T: 540VDC rating, MPPT range 500VDC~700VDC(Note 2)
004:4kW;5R5:5.5kW;R: decimal point
General Parameters
Protection
Integrated
Integrated
Locked pump Protection
Integrated
Integrated
Communication
Others
-20°C~60°C;>45°C, Derating as Required
IEC/EN 61800-5-1,IEC/EN 61800-2:2004,IEC/EN61800-3:2004,CE
- 12 -
Options
Overvoltage Protection
Short circuit Protection
Dry Run Protection
Isolation RS485
Optional
Fan Cooling
≤ 95%RH
18
Integrated
Integrated
Integrated
Integrated