11. CARE OF ELECTRODES

The electrodes that are supplied with your Flexistim IF are self-adhesive and can be used
several times. Skin must be allowed to breathe, so the electrodes should be removed
periodically. When not in use, the electrodes should be placed onto the clear plastic shield.
L2
The condition of the electrodes has a direct effect on conductivity and therefore the
effectiveness of the treatment. When the electrodes start to lose their adhesive quality,
it is possible to reactivate their adhesiveness by applying a fine spray of water to the gel
L1
side of the electrode. In time, this technique will not work, the gel will not reactivate and
new electrodes should be used.
GENERAL PAD ADVICE
• The electrode pads supplied are reusable but are for single patient use.
• In order to obtain the best conductivity through the pads always ensure that they are in
good condition and tacky.
• Before use make sure your skin is clean and dry.
• Peel the electrode pads from their protective plastic shield by holding and lifting one
corner of the pad and pulling. Do not pull on the pigtail wire of the pad.
• After use always replace the pads on the plastic liner and replace in the re-sealable plastic bag.
• If the pads dry out then it is best to buy a replacement pack of electrodes. In an emergency
it may be possible to restore some of the tackiness of the pad by adding a tiny drop
of water on each pad and spreading around. If too much water is added the pads will
become too soft then it is suggested in order to try to re-establish some adhesiveness to
place them sticky side up in a refrigerator for a few hours.
• In very hot weather the gel on the pads may become soft. In such cases place the
pads, still on their plastic liners and in their bag, into a fridge until they return to their
normal condition.
L2
WARNINGS
Do not use any electrodes less than 50mm X 50mm.
Allergic reactions to the self-adhesive electrodes can occur even though they
are hypoallergenic.
• Do not apply to broken skin.
• Do not apply electrodes to areas with less than normal sensitivity. This could lead to
setting intensities at higher levels than intended.