Inputting Numeric Settings
Standard Screen (Screen Attribute: System)
1
2
7
8
Creating Numeric Setting
Screens
Inputting Numeric Values
(PTs With Touch Panels)
Inputting Numeric Values
(PTs Without Touch Panels)
48
ments and functions are fixed. In order to change the key arrangement or
add keys (such as a decimal point) for numeric input, set the "numeric set-
ting" item under "screen attributes" to "user." (When it is set to "system," the
standard screen will be displayed.) For instructions on registering numeric
setting screens, refer to the NT-series Support Tool Operation Manual.
3
4
5
6
9
0
CLR
+/–
When creating a numeric setting screen with the Support Tool, take note of
the following points.
1) A numeric setting screen cannot be set as the child screen of a continuous
screen.
2) Ordinary touch switches can be set in numeric input screens, but touch
switch numbers 244 through 255 cannot be used.
3) When "10-key" is set to "user" in the screen attributes, touch switch num-
bers 231 through 255 cannot be used for purposes other than numeric input.
4) The numeric setting function cannot be used when the screen attribute "bit
input" is enabled for PTs with no touch panel.
1) Inputting Numeric Values with the Standard Screen:
• The numeral shifts from the rightmost digit to the left each time a screen
key is pressed.
• If a decimal point is set, the shift is from the rightmost digit in the decimal
area to the integer side.
2) Inputting Numeric Values with a User-set Screen:
• The numeral shifts from the rightmost digit to the left each time a screen
key is pressed.
• If a decimal point is set, the integer portion is received first, and with each
numeric key input there is a shift from the rightmost digit to the left.
• When the decimal point key is pressed, the decimal portion will then be re-
ceived. From that point on, with each numeric key input there is a shift from
the rightmost digit in the decimal portion to the left.
Use the 12-key Function Key Unit (NT20M only) or the 32/16 Terminal for an
External I/O Unit. The 10/02 Terminal cannot be used for numeric input.
1) Inputting Numeric Values with the Standard Screen:
Use the corresponding function keys. Numeric input is the same as for PTs
with touch panels.
User-set Screen Example
(Screen Attribute: User)
HOME
Tank A
Tank B
1
0654
0650
4
Tank C
Tank D
7
0000
0550
0
Tank E
Tank F
0800
0990
CHANGE
Section 5-2
MENU
2
3
5
6
8
9
.
CLR
SET