Target Group

Skilled personnel recognized
This manual and the tasks and procedures described herein are intended for use by skilled workers only.
A skilled worker is defined as a trained and qualified electrician or installer who has all of the following skills and expenence:
• Knowledge of the functional principles and operation of on-grid systems.
• Knowledge of the dangers and risks associated with installing and using electrical devices and acceptable mitigation methods.
• Knowledge of the installation of electrical devices
• Knowledge of and adherence to this manual and all safety precautions and best oractices.

Installation environment requirements

Max.
Min.
-10℃
+50℃

Tools

Sleeves

Packing list

Cabinet

Installation steps

1.
Unpacking
BYD Battery-Box Pro
QUICK REFERENCE GUIDE
Valid for Battery-Box Pro 2.5/5.0/7.5/10.0
RH.
+5%~+95%
Power cable ×1
Leveling Mounts
Cabinet
B-Plus L 2.5
Phillips screwdriver
×4
2.
Install anchor bolt
IP20
Only indoor installation
Wrench
B-Plus
B-Plus
Grounding cable
network cable
power cable +
power cable -
V5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Battery-Box Pro 2.5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BYD Battery-Box Pro 2.5

  • Page 1: Target Group

    BYD Battery-Box Pro QUICK REFERENCE GUIDE Valid for Battery-Box Pro 2.5/5.0/7.5/10.0 Target Group Skilled personnel recognized This manual and the tasks and procedures described herein are intended for use by skilled workers only. A skilled worker is defined as a trained and qualified electrician or installer who has all of the following skills and expenence: •...
  • Page 2 Connecting power cables Install B-Plus L 2.5 Openthedoor&removethesidedoor U3A1-50P-A RS485/RS232 RS485/RS232 RUN ERR ARM ADDR ON/OFF U3A1-50P-A U3A1-50P-A RS485/RS232 RS485/RS232 RS485/RS232 RS485/RS232 RUN ERR ARM ADDR ON/OFF ADDR ON/OFF RUN ERR ARM U3A1-50P-A RS485/RS232 RS485/RS232 ADDR ON/OFF RUN ERR ARM U3A1-50P-A U3A1-50P-A RS485/RS232 RS485/RS232 ADDR ON/OFF RUN ERR ARM RS485/RS232 RS485/RS232...
  • Page 3 If more than two inverters are installed in the system, Install switches for DC BUS eachinverter. (BecauseaftertheBattery-Boxstarts,willchargetotheinverterthecapacitance,in theshorttimethecurrentisverybig,causestheBattery-Boxtoentertheprotection mode,cannotcontinuetochargetotheinverter,inthiscase,theinverterwillnotbe abletostart.) TheaddressoftheBMSmuststartwith1,mustbeconsecutive,cannothave0. master OnlytheBMUwiththelastaddressisconnectedtotheinverter. Battery-BOX Battery-BOX Battery-BOX Battery-BOX Battery-BOX Thismanualisashortenedassistancefortheinstallationofthe DieseAnleitungstellteineverkürzteAufbauhilfedar,undersetztnichtdieoriginal Battery-Boxanddoesnotreplacetheoriginalmanual,whichcanbe AnleitungderBattery-Box,erhältlichaufwww.eft-systems.deoderwww.byd.com. foundonwww.eft-systems.deorwww.byd.com.Theinstallationmust InstallationdarfnurvonFachleutendurchgeführtwerden.AchtungLi-IonenSpeicher! becarriedoutbyaqualifiedexpert.Attention,Li-IonStorage!Improper BeiunsachgemäßerHandhabungkannGefahrfürLeibundLebenentstehen. handlingcancausedangeranddamage. FürweitereInformationenoderKontakt:www.eft-systems.de Australia : http://alpspower.com.au...
  • Page 4 Check Is the power cables connection correct? Is the communication cable  connected correctly? Has the battery's address been set correctly? Is the battery reliably grounded? Is the inverter set correctly? Are the other connections and setting correct? How to start and power off the system Start ON/OFF Press “ON/OFF” to start the battery Thebattery'sLEDflashes,andafter4secondstheSOCLEDgreenlightandtherungreenlight,thebatteryisstartednormally. According to inverter manual, start inverter correctly Turnoffallloadsbeforestartingtheinverter. Turn on the load and power in Input/outputneedstomeetbatteryandinverterratings. Ratingscanbefoundinspecificationsorusermanuals. Power off Close the power of loads and input. Close the inverter according to inverter manual ON/OFF Press the on / off button for 4.5 seconds to close the battery Shutdownallbatteries. Warning: incorrect ordering can cause the system can’t work normally or even to be damaged! If the system does not work, please turn off the battery before you leave to avoid damage caused by the battery vent. LED Indications RS485 RS485 LEDoff ADDR ERR ALM LEDblink ON/OFF LEDilluminated description Statu Reason Disposal method ERR ALM allLEDwasoff Batteryoff allLEDwasblink...

Table of Contents