Norcold EV0041 Service Manual page 10

Dual electric refrigerator
Hide thumbs Also See for EV0041:
Table of Contents

Advertisement

Procedure C: Temperature Control ON, Power Indicator Off, Compresssor Does Not Run
Check
ccnnections,
in-line
fuse and DC
Power
Supply
fuse.
NO
YES
Measure
DC Power Supply
output
to
compressor.
See
1---<
Figure #and
text below.
NO
Measuring Power Supply Output, Compressor Disconnected
A
cAUTION!
Do not use a converter or battery charger to supply
DC power to the refrigerator. These devices do not
supply filtered DC power. When Using a converter
or battery charger, make sure that a battery is
connected
in-line
between them.
1. Connect
the
DC power supply to a charged 12 volt
automotive battery. Observe the correct polarity
(red+/
black-)
when
connecting the DC Power Supply wires to
the battery.
2. Disconnect the line
voltage wire
from the compressor.
3. Tum on the
refrigerator.
The power light should illuminate.
4. Measure voltage output at line voltage connector. See
Figure 14. Voltage values
with
the compressor
disconnected
:
DEIEV0041
DEIEV0061
17 to 25 Vac.
17 to 25
Vac.
The DC power supply must be replaced if the voltage output
is not
within
the specified values.
5.
Shift operation to AC power. Plugging the ACcord to a
"live" 120 Vac outlet
will automatically
shift refrigerator to
AC
operation
.
6.
Measure voltage
at compressor.
See
Figure 14, See step
4
for
voltage
output
values.
No voltage! or voltage is
lower
or
higher than
values
listed
in
Step
4,see
Procedure D,
page
11.
Check
polarity,
repair
ccnnections
or
replace
fuses as
required
.
Check polarity, repair
ccnnections
or
replace
fuses as
required.
Correct
Vac output.
proceed to
Procedure#.
Power Switchl
/Thermostat
Power Indicator
/
(Green
LED)
D
C
Power Input
'f~res
Red: Positive
( +)
Black: Negative(-)
Figure 14.
Checking
DC Power
Supply voltage output.
10
f5d£1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

De0061De0041Ev0061