Battery Installation & Replacement
If a sensor battery is low, a low battery notification will be indicated on the 2GIG Alarm Control Panel's screen. When the
2GIG alarm system Indicates that there is a sensor with a low battery, replace the battery immediately. Use only the
recommended replacement batteries (see Specifications).
To install or replace the battery, do the following:
1
To remove the sensor cover, use your finger to press the tab on the end of the case. This will disengage the clip holding
the cover to the base.
2
Place a small flathead screwdriver in the slot between the metal clip (see Figure 3) and the battery and push it out taking
care not to scratch the battery terminal on the PCB.
3
Insert the replacement battery with the + sign facing out (see Figure 3).
4
Verify programming and RF communication with the panel (see Testing).
WARNING! The polarity of the battery must be observed, as shown (see Figure 2). Improper handling of lithium
batteries may result In heat generation, explosion or fire, which may lead to personal injuries. Replace only with
the same or equivalent type of battery as recommended by the manufacturer (see Specifications).
Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be made In
accordance with the waste recovery and recycling regulations In your area.
Keep away from small children. If batteries are swallowed, promptly seek medical attention.
California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY In
California, USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.

Specifications

Wireless Signal Range
Code Outputs
Supervisory
Transmitter Frequency
Transmitter Frequency Tolerance
Transmitter Bandwidth
Modulation Type
Unique ID Codes
Supervisory Interval
Peak Field Strength
External Input Sampling Current
External Input
Reed Switch Magnetic Sensitivity
Reed Sensitivity
Magnet Type
Magnet Dimensions (Hx~)
Sensor Dimensions (HxD)
Weight (Including battery & magnet)
Housing Material
Color
Operating Temperature
Relative Humidity
Battery (Installed with pull tab)
Regulatory Listing(s)
Warranty*
Included Accessories
FCC & INDUSTRY CANADA REGULATORY INFORMATION
FCC ID: WDQ-DW11345
Industry Canada ID: 7794A-DW11345
NOTICE: Unauthorized changes or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
.
Reorient or relocate the receiving antenna.
.
Increase the separation between the equipment and the receiver
.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
.
Consult the dealer or an experienced radio/television technician for help
©
2011 2gig Technologies Inc. All Rights Reserved
350 ft., open air, with 2GIG Wireless Alarm Control Panel
Alarm Restore; External Alarm; External Restore; Tamper; Tamper Restore
Low Battery
345.000 MHz (crystal controlled)
± 15kHz
24kHz
Amplitude Shift Keying-On/Off Keying (ASK-OOK)
Over one (1) million different code combinations
70 minutes
Typical 36,000 uV /m at 3m
20 uA
Accepts N/C dry contact devices
10 to 20 amp turns
0.625 in. (1.59 em) minimum gap, 0.85 in. (2.16 em) typical
Rare earth
1.3 X 0.435 X 0.312 in. (3.3 X 1.1 X 0.79 cm)
2.59 X 1.03 X 0.49 in. (6.58 X 2.62 X 1.24 cm)
1.1 oz. (31.2 g)
ABS plastic
White
32° to 120°F (0° tO 49°C)
5-95% Non-Condensing
One (1) Panasonic CR2032, or equivalent Lithium batteries
ETL, FCC Part 15, Industry Canada
Two (2) years