SKC ULTRA 690-200 Operating Instructions

SKC ULTRA 690-200 Operating Instructions

User-filled passive sampler

Advertisement

Quick Links

User-fi lled ULTRA Passive Sampler
Clip
Diffusion holes
(sample sorbent
compartment)
Blank/
correction
sorbent
compartment
Sliding cover in open
(sampling) position
Applications
SKC patented* user-fi lled ULTRA
detection of organic vapors in ambient and indoor air. Filling the sampler is simple
and provides a wide variety of sorbent options and a longer shelf-life.
* U.S. Patent No. 6,607,581
Performance Profi le
Sampling Rates: Go to the SKC Passive Sampling Guide at
Analysis:
Shelf-life:
Cat. No. 690-200
Clip
Sample
compartment
Sliding
cover
Blank/
correction
compartment
Sliding cover in
closed position
®
Passive Sampler provides for low ppb to ppt
www.skcinc.com/catalog/passive-guide.php.
Thermal desorption; gas chromatography
See Analysis Instructions at www.skcinc.com/instructions/40125.pdf.
Sorbent vials containing Tenax
Carbopack X, or Anasorb
≤ 39.2 F (4 C).
Sorbent vials containing Charcoal have a one-year shelf-life
at ≤ 39.2 F (4 C).
www.skcinc.com
Operating Instructions
863 Valley View Road, Eighty Four, PA 15330 USA
Tel: 724-941-9701 • www.skcinc.com
Clip
Sample sorbent
compartment
Sliding
cover
Blank/
correction
sorbent
compartment
®
TA, Chromosorb
®
GCB1 have a 60-day shelf-life at
Back view
®
106,
Plugs

Advertisement

loading
Need help?

Need help?

Do you have a question about the ULTRA 690-200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SKC ULTRA 690-200

  • Page 1 Filling the sampler is simple and provides a wide variety of sorbent options and a longer shelf-life. * U.S. Patent No. 6,607,581 Performance Profi le Sampling Rates: Go to the SKC Passive Sampling Guide at www.skcinc.com/catalog/passive-guide.php. Analysis: Thermal desorption; gas chromatography See Analysis Instructions at www.skcinc.com/instructions/40125.pdf.
  • Page 2 Once all sorbent has been transferred from the vial, remove the funnel, and replace the plug on the compartment access port. If a blank/correction is required, remove the plug Plug from the blank/correction compartment (on right Clip side, immediately above SKC cover). Blank/ Repeat Step 3. correction compartment Sliding cover Open second vial and repeat Steps 4a.
  • Page 3 Sliding cover Stop sampling: Slide sampler cover to closed position (arrow and SKC visible). Write sample Sample compartment stop time on pouch label. Important: Measure and record ambient temperature Clip and atmospheric pressure. Include in information sent Blank/ to the laboratory.
  • Page 4 Ω Can be stored for up to one year at ≤ 39.2 F (4 C) SKC Limited Warranty and Return Policy SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability and the buyer’s exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to htt p://www.skcinc.com/warranty.