- If the room temperature is too high, decrease the heat-
ing curve slope value.
Warm weather:
- If the room temperature is too low, turn the roller to
Comfort set point, heating clockwise 0.5°C, and press
the OK button.
- If the room temperature is too high, turn the roller to
Comfort set point, heating counter-clockwise to 0.5°C,
and press the OK button.
NOTE! Wait one day between settings so that temperatures have
time to settle down.

11.6 Selecting heating mode

The heat pump can be used with different operating modes. The
difference between the operating modes are the temperatures.
The operating mode is changed in the Operating mode menu
Automatic operation
In automatic operation the room temperature is adjusted accord-
ing to a time program. Automatic operation's features:
Heating mode according to time program.
Temperature set points according to the heating mode
type "comfort set point" or "reduced set point".
Protection operations are always active
Automatic summer/winter mode switch connection
activate.
Continuous comfort or reduced operation
In continuous operation, the temperature is continuously kept at
a selected level.
Features of continuous operation:
Heating mode without time program
Protection operations active
Automatic summer/winter mode switch connection is
out of use.
Protection operation
In protection operation the heating system is turned off. Its frost
protection is, however, active (frost protection temperature),
provided that the voltage supply is not cut off.
Features of protection operation:
v1-6 29082018
Heating areas off
Temperature according to frost protection tempera-
ture
Protection operations active
Summer/winter mode switch automation is active.

11.7 Domestic hot water settings

The heat pump produces domestic hot water with the change-
over valve. The change-over valve turns the water flow to the
domestic hot water reservoir, in which case heat is not charged
to the property.
The domestic hot water reservoir's water temperature varies be-
tween the set points (nominal set point – switching differential
5°C).
The domestic hot water temperature is set in the
Factory setting: 55°C
The domestic hot water heating can be switched on and off by
pressing the Operation mode Off
When the domestic hot water's charging operation is active (Op-
eration mode On), the domestic hot water is heated according to
the selected set point. When the charging operation is switched
off (Operation mode Off), the domestic hot water's charging is
not on.
The manual charging of domestic hot water can be activated by
setting the Temporary setting on the user terminal or room unit
to "Recharge". This operation activates charging and charges the
domestic hot water to the set point.

11.8 Heat pump's Reset function

The heat pump's active failure messages from the Regional set-
tings menu. The preset activation delay is not taken into consid-
eration, so undesired delays are avoided during commissioning
and troubleshooting.