Technical data

7.1

Sensor

Electrical connection
Supply voltage:
XT-1000
Process connection
Sensor head
Probe tube
Communication
XT-1000
Two-line terminal
4 to 20 mA (3.8 to 20.5 mA) current consumption for level display
21.5 mA (3.6 mA) current consumption in failure mode
8 to 30
V DC
Screw-in unit with the option of infinitely variable
height adjustment
Standard G ½ (cutting ring coupling)
3" Ansi Flange
2" NPT screw-in unit
Height 4.53"
Diameter 1.97"
Index of protection IP 68
Material: stainless steel
Cable diameter 0.2" to 0.4"
Temperature –40 °F to +185 °F
Length 8" to 19' (to order)
Diameter .47"
Material: 1.4571 standard
(titanium, Hastelloy C, or other materials on request)
Measuring range freely configurable (> 0.4")
Normal temperature (NT)
High temperature (HT)
Ultra high temperature (HHT)
Low temperature (LT)
HART protocol (optional)
-40 °F to +250 °F
-40 °F to +450 °F
-40 °F to +840 °F
-85 °F to +250 °F
Page 17/19