Electrical connection

It is essential that the correct minimum wire gauge be selected: the supply voltage at the
level sensor must not fall below 8 V in the event of maximum current draw (21.5 mA).
The sensor head and probe tube of XT-1000 Standard are made of stainless steel.
The level sensor without Ex approval is installed in accordance with the following wiring
diagram:
Figure 6: wiring diagram for XT-1000
To connect the level sensor, see Figures 7:
Unscrew sensor head cap (1) using an open-ended spanner.
Loosen union nut (2) of screwed cable gland (3).
Figure 7: connecting the XT-1000 level sensor