Use only RG‐6 CATV cable between the MRAU and SRAU, the lengths of which are listed below.
Belden 1695A Coax Specifications

Description

RG‐6/U type, 18 AWG solid 0.040‐inch bare copper conductor, plenum, foam FEP insulation,
Duofoil
®
+ tinned copper braid shield (95% coverage), Flamarrest
Overall Physical Characteristics
Conductor
Insulation
Outer Shield Layer 1
Outer Shield Layer 2
Outer Jacket
Overall Cabling
InterReach Spectrum Remote Access Unit Installation Guide
TECP-77-222 • Issue 1 • August 2012
RG-6 Cable
Meters Feet
Typical
800/900 iDEN to 850 CELL
800 AWS to 850 CELL
One Coax
18 AWG
Solid stranding
Bare Copper (BC) conductor material
0.040‐inch diameter
®
Teflon
Foam Fluorinated Ethylene Propylene (FFEP)
0.170‐inch diameter
®
Duofoil
Tape
Aluminum Foil‐Polyester Tape‐Aluminum Foil
100% coverage
Braid
Tinned Copper (TC)
95% coverage
Flamarrest
Low Smoke Polyvinyl Chloride (LS PVC)
0.234‐inch overall nominal diameter
2
6.56
6
19.68
6
19.68
®
jacket.
®