Appendix B: 75-Ohm Catv Cable; Catv Cable Requirements - TE Connectivity SPT-M1-8519-1 Installation Manual

Remote access unit
Table of Contents

Advertisement

Appendix B: 75-Ohm CATV Cable

A
 B: 75‐O
PPENDIX
The 75‐Ohm CATV Cable:
connects the IFEU to MRAU(s) and the MRAU(s) to the SRAU(s)
transmits (FWD) multiband and receives (REV) IF signals
delivers DC electrical power to the RAUs. The Spectrum IFEU DC voltage output is +54Vdc
nominal. If the IFEU reaches its current limit, a current‐limiting circuit protects it.
carries configuration and status information
uses 75
type‐F connectors with captive center pins.
CATV Cable Requirements
Belden CATV cable or equivalent is required (see Figure 2).
For the RG‐6 cable, use a Belden 1695A Coax.
For the RG‐11 cable, use a Belden 7732A Coax.
NOTE:
TE Connectivity requires solid copper center conductor CATV cable for proper DC voltage to the 
RAU and maximum distances.
Use RG‐6 or RG‐11 CATV cable between the IFEU and MRAU, the typical lengths of which are
listed below.
Page 20
© 2012 TE Connectivity Ltd
 CATV C
HM
ABLE
RG-6
Belden 1695A Coax
Figure 2. 
Belden 1695A and 7732A Coax Cables
Minimum Length Maximum Length
Cable Type
Meters
RG-6
0
RG-11
0
RG-11
Belden 7732A Coax
Feet
Meters
Feet
0
140
459
0
200
656
InterReach Spectrum Remote Access Unit Installation Guide