4
Specifications
Technical data for sensor DB 112 UP
Sensor data
Operating range
Converter frequency
Ultrasonic lobe
Mechanical data
Housing
Weight
Connection type
Technical data for analysis amplifier VDB 112 B/...
Timing
Switching frequency
Input pulse
Delay before start-up
Electrical data
Operating voltage U
Residual ripple
Open-circuit current
Switching output
Function
Signal voltage high/low
Output current
Teach input
TEACH-IN active/not active
TEACH IN duration
TEACH IN delay
Indicators
LED green A
LED A yellow
LED A red flashing
LED yellow B
LED red C
Mechanical data
Housing
Weight
Connection type
Environmental data
Ambient temp. (operation/storage)
Protective circuit
VDE safety class
Protection class
Standards applied
Certifications
1)
For UL applications: only for use in "Class 2" circuits according to NEC.
2)
Function:
The push-pull switching outputs must not be connected in parallel
3)
Setting the Teach IN input disables the TEACH IN button (see page 10)
4)
Only applies for automatic calibration during sheet movement (automatic teach)
5)
1=transient protection, 2=polarity reversal protection, 3=short circuit protection
6)
These proximity switches shall be used with UL Listed Cable assemblies rated 30V,
0.5A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
6
1)
B
3)
4)
5)
.../...P = active high (+24V); inactive low (0V),
.../...N = active low (0V); inactive high (+24V).
DB 112 B
15 ... 30mm
300kHz ±5%
approx. 12°
nickel-faced brass
30g
1.5/2.5m cable with M8 connector,
3-pin, bending radius r > 25mm
200Hz
min. 5ms
≤ 300ms
18 ... 30VDC (incl. residual ripple)
≤ 15% of U
B
≤ 75mA
2 push-pull switching outputs
single sheet detected, or ≥ 1 sheet
double sheet detected, or ≥ 2 sheets
≥ (U
- 2V) / ≤ 2V
B
max. 100mA per output
R
= 10kΩ
in
.../...P (PNP): ≥ 10V / ≤ 2V or not connected
.../...N (NPN): ≤ 2V / ≥ 10V or not connected
max. 100ms
approx. 300ms
double sheet testing unit ready
teach-in process
error (see chapter 9)
single sheet detected
double sheet detected
aluminium, black powder-coated
400g
M12 connector, 5-pin
0°C ... +50°C / -40°C ... +70°C
1,2,3
III
IP 65
EN 60947-5-2
UL 508, C22.2 No.14-13
2)
1) 6)