9
Diagnosis in the case of error
The device LEDs indicate the following error states:
LED
red
flashing
(6Hz)
red
flashing
(6Hz)
red
flashing
(6Hz)
red
flashing
(6Hz)
red
flashing
(3Hz)
Leuze electronic
LED
LED
yellow
flashing
(6Hz)
red
red
flashing
(6Hz)
red
flashing
(6Hz)
rapid
rapid
yellow
red
flashing
flashing
red
Diagnosis in the case of error
Meaning
Double-sheet con-
trol not calibrated
No single sheet
No sheet inserted or
detected during cali-
double sheet
bration
inserted
Amplifier detects
Sheet between the
insufficient input sig-
sensors or sensors
nal when device
not connected
switched on
Amplifier detects
excessively high
Extreme back-
noise level when
ground noise
device switched on
Current at output too
Short circuit
high
Fatal memory error
Defect
DB 112 B
Cause
Remedy
Perform calibration
Calibrate on single
sheet
Remove sheet and
acknowledge with
the TEACH IN button
Dampen back-
ground noises, e.g.
using foam
Switch off voltage,
check wiring
Have repaired by
Leuze electronic
13