Installation manual Self cleaning decoration panel BYCQ125BGW1 1. Safety Considerations CAUTION Please read these “Safety Considerations” carefully before installing • Install the indoor and outdoor units, power cord, remote controller air conditioning equipment and be sure to install it correctly. wiring, and transmission wiring at least 1m away from TV or radio After completing installation, conduct a trial operation to check for sets.
3. Accessory * Point of operation explanation In addition to the general usage of the air conditioner, it is Check that the following accessories provided with the air necessary to explain the descriptions of the WARNING and conditioner are correct in number. See the following illustration, CAUTION marked items in the operation manual and have which shows where the accessories are kept.
Page 5
Required installation space Install the indoor unit according to the installation manual and the following illustrations. Indicator Sensor Dust collection inlet Front side of panel [Required installation space] Refer to the installation instructions of the indoor unit and install the product according to the following figure. Dust collection Indoor Exhaust...
5. Preparations for Panel Removal of decoration corner covers Decoration corner cover Note Decoration • Perform all the required work in "5. Preparations for Panel" on Decoration corner cover corner cover page 4 with the panel kept in the packing material (on the bottom side).
Attaching spacer (accessory (1)) (1) Turn the 2 fixing knobs of the dust box. Fixing knob Dust box (1) Remove the bypass hole closing cap. Fixing knob (The front side of the panel is shown for ease of explanation.) (2) Remove the dust box from the panel while paying attention not Indoor unit to cut the fall prevention cord.
Attaching panel (2) Remove jumper connector from X8A. (1) Tentatively put the two temporary latching brackets of the suction port of the panel (on the internal circumference side) to the hooks of the indoor unit. Note Let go your hands after confirming through the check window that the temporary latching brackets are engaged with the hooks.
Page 9
(2) Draw the harness and lead wires (on the panel side). Lower part of hook of 7-2 (6) the indoor unit Panel Panel Indoor unit (The ceiling is omitted from the Lead wire illustration for ease (on the panel side) Harness of explanation) Lower side...
Page 10
(7) Connect the swing lead wire connector to the Printed circuit (1) Hook the fall prevention cord for the dust box to the panel board. clasp as shown in the illustration. Printed circuit board Connect the swing lead wire connector to the Printed circuit board Clasp Be sure to connect them securely.
8. Attaching Suction Grille and (3) Connect the flexible hose (accessory (2)) onto the panel side. (The flexible hose (accessory (2)) has no directionality constraint.) Decoration Corner Covers Flexible hose junction The suction grill can be rotated and attached in two directions, on the panel side either one of which is selectable.
Page 12
(6) Push up the suction grille slowly first, and while pressing the (3) Connect the flexible hose (accessory (2)) onto the panel side. two knobs, finally fit the grille into the panel securely. (The flexible hose (accessory (2)) has no directionality constraint.) Panel Knobs...
(4) Attach the decoration corner covers (i.e., the three covers) to Note the panel. The suction grille can catch the fall prevention cords while the suction grill is closed. Check that the fall prevention cords do not protrude from the suction grille before closing the suction grille.
Make field settings according to the installation manual of the remote controller. (Settings in bold cells are made before shipping.) Cool Set to FIRST SECOND CODE NO. Press and hold Cool °F Setting Mode CODE Cancel button for 4 seconds or item longer during Display...