Download Print this page

Daikin BYCQ125BGW1 Operation Manual

Self cleaning decoration panel
Hide thumbs Also See for BYCQ125BGW1:

Advertisement

Decoration Panel Provided with Filter Auto-cleaning Function
Self Cleaning Decoration Panel
BYCQ125BGW1
Proper Use for Effective Energy Savings
• Thank you for purchasing the self-cleaning panel.
• This manual describes safety considerations which should be
observed during the use of the product.
Read this manual carefully and be sure you understand
the information provided before attempting to use the
product.
Keep this manual where it is readily accessible after reading.
If another user operates the product in the future, be sure to
hand over this manual to the new user.
• This operation manual is dedicated to the decoration panel
provided with a filter auto-cleaning function.
Read this manual along with the operation manual provided with
the wired remote controller.
3P225748-4G
OPERATION MANUAL

Advertisement

loading

Summary of Contents for Daikin BYCQ125BGW1

  • Page 1 OPERATION MANUAL Decoration Panel Provided with Filter Auto-cleaning Function Self Cleaning Decoration Panel BYCQ125BGW1 Proper Use for Effective Energy Savings • Thank you for purchasing the self-cleaning panel. • This manual describes safety considerations which should be observed during the use of the product. Read this manual carefully and be sure you understand the information provided before attempting to use the product.
  • Page 2 • Contact your dealer for repair and maintenance. completing the installation, make sure that the unit operates properly during the startup operation. Instruct the customer Improper repair and maintenance may result in water on how to operate and maintain the unit. leakage, electric shock, and fire. Only use accesso- Inform customers that they should store this Operation ries made by Daikin that are specifically designed for Manual with the Installation Manual for future reference. use with the equipment and have them installed by a Meanings of DANGER, WARNING, CAUTION, and NOTE professional. Symbols: • Contact your dealer to move and reinstall the air conditioner or heat pump.
  • Page 3 Safety Considerations may get discolored or the coating can peel off. If it is CAUTION heavily dirty, soak a cloth in water-diluted neutral • Do not use the air conditioner or heat pump for any detergent, squeeze it well and wipe the panel clean. other purposes other than comfort cooling or heat- Then wipe it with another dry cloth. • Dismantling of the unit, disposal of the refrigerant, ing.
  • Page 4: Table Of Contents

    Contents Safety Considerations ................ i Names and Functions ................ 2 Filter Auto-cleaning .................. 5 Dust Collection from Dust Box .............. 1 0 Filter Maintenance .................. 1 4 Useful Information .................. 1 5 3P225748-4G English...
  • Page 5: Names And Functions

    Names and Functions Filter fixing knobs Control box (in 5 points) of panel Dust box Decoration fixing knobs Indicator Decoration corner cover corner cover (in 2 points) (green/red) Indicator Floor temperature sensor* (green/red) Louver Senses the average Dust box temperature of Decoration the floor Brush unit...
  • Page 6 This remote controller is the BRC1E73 model. Other remote controllers may vary in display. 1. Operation mode selector button 11. L CD (with backlight) 4. Up button 5. Down button 6. Right button 7. Left button 9. Operation lamp 8. On/Off button Mode On/Off 3.
  • Page 7 Names and Functions 9. Operation lamp 6. Right button • Used to highlight the next items on the right- • This lamp illuminates solid green during normal hand side. operation. • Each screen is scrolled in the right-hand • This lamp flashes if an error occurs. direction. 10. Cancel button 7. Left button • Used to return to the previous screen. • Used to highlight the next items on the left-hand 11. LCD (with backlight) side. • Each screen is scrolled in the left-hand • The backlight will be illuminated for direction. approximately 30 seconds by pushing any button. 8.
  • Page 8: Filter Auto-Cleaning

    Filter Auto-cleaning Operation procedure Remote Controller Functions Operation button display Explains a button operation procedure for the remote controller. Displays the positions of buttons to Operate the buttons according to the procedure. be operated. Operation Method • Push buttons to select the Filter Auto Clean on the Main Menu...
  • Page 9 Filter Auto-cleaning • The period will change whenever buttons are pushed in Filter Auto Clean the Clock setting screen for filter auto-cleaning. Filter Auto Clean 12:00 –3:00 , 3:00 –6:00 , 6:00 –9:00 , 9:00 –12:00 , 12:00 – 3:00 12:00 –3:00 , 3:00 –6: 00 , 6:00 –9:00 , 9:00 –12:00 Select the desired period from the ones displayed. Setting • Push Menu/OK button. The settings confirmation screen will appear. • Push button to select Yes on the settings confirmation Filter Auto Clean screen.
  • Page 10 PREPARATION • To designate a period for filter auto-cleaning, avoid selecting the periods of time when the product is in air conditioning operation as much as possible. If the period for filter auto-cleaning overlaps with that for the air conditioning operation of the product, the product may stop air-conditioning forcibly and start filter auto-cleaning. • If the message “Set clock from menu” appears, make clock settings again so that the filter auto-cleaning will be performed during the designated period. NOTE * T he product will be set to auto control operation mode unless clock settings are made again if the clock is reset for some reason (e.g., no power is supplied to the product for 48 hours or longer). • The product may generate a little noise when the filter rotates or the dust is scraped with the brush. • The fan rotates automatically during filter auto-cleaning. Clock & Calendar „Setting the clock Operation Method • Push Menu/OK button. Cool Set to Return Setting Basic screen • The main menu screen will appear. Main Menu Airflow Direction Individual Airflow Direction Quick Start...
  • Page 11 Filter Auto-cleaning • Select “Month” with buttons. Date & Time Input the month with buttons. Year 2015 Month Holding down the button causes the number to change Sunday continuously. 12:00 Setting • Select “Day” with buttons. Date & Time Input the day with buttons. Year 2015 Month 2 Holding down the button causes the number to change Wednesday continuously. 12:00 Days of the week change automatically. Setting • Select “Hour” with buttons. Date &...
  • Page 12 Current Settings „Manipulating the current settings Operation Method • Display the main menu screen. (Refer to page 7) Main Menu • Push buttons to select Current Settings on the main Maintenance Information Configuration menu screen and push Menu/OK button. Current Settings Clock & Calendar Daylight Saving Time Language Setting • A list showing the current setting status will appear. Current Setting Push buttons to go to the next item. Airflow Direction Schedule Disable •...
  • Page 13: Dust Collection From Dust Box

    Dust Collection from Dust Box Dust Collection Sign Display The collection sign will indicate to notify the dust collection at the advent of cleaning time. Promptly collect the dust when the sign is confirmed. * T he dust collection sign will appear at intervals of approximately half a year to one year. The intervals may become shorter if the product is used in places with excessive dust. The dust collection sign will appear in a stepwise manner according to the quantity of dust in the dust box. Place of display Collection sign 1 Collection sign 2 Collection sign 3 Collection sign 4 The messages “Collect dust” and “Push Menu Button” will “AH” (error sign) appear alternately. will appear Remote controller Operation No indication The operation lamp will flash. lamp The indicator will Decorative corner cover...
  • Page 14 Dust Collection with Vacuum Cleaner Vacuum the dust in the dust box on completion of confirming the dust collection sign. NOTE • Dust collection with a vacuum cleaner is not possible during filter auto-cleaning. Make sure that “ ” is AUTO CLN FILTER not displayed on the remote controller screen before dust collection. * The indicator will flash green if it is set to display. (Refer to page 2) Insert the connecting pipe and attachment (optional accessory) meeting the size of the vacuum cleaner pipe. The KKHAP55B160 (optional accessory) consists of a connecting pipe and attachment. Insert the connecting pipe attachment into the vacuum cleaner pipe. Vacuum cleaner pipe with an inner Vacuum cleaner pipe with an inner diameter of 1-1/4 (32) to 1-1/2 (38)
  • Page 15 Dust Collection from Dust Box While the leading end of the connection pipe closely come in contact, turn on the vacuum cleaner with the suction power set to maximum power and vacuum the dust. If the indicator on the decorative corner cover is flashing red, the indicator will be turned off or lit green on completion of dust collection. * It may take a maximum of 30 seconds for the indicator flashing red to be turned off or lit green. 3P225748-4G English...
  • Page 16 Resetting Dust Collection Sign Operation Method • When the time for collecting dust from the dust box comes, the dust collection messages “Collect dust.” and “Push Menu Auto Set to Cool Button.” will appear alternately on the lower part of the basic Cool screen. Heat • At the time of this state, push the Menu/OK button on the Collect dust basic screen. Basic screen • An illustration of vacuuming dust from the dust collection inlet Dust Collection Method will appear. (Refer to “Dust Collection with Vacuum Cleaner” on page 11) • After understanding the method of dust collection, push the Menu/OK button at the time of this state. Setting • After vacuuming the dust in the dust box, push buttons Dust Collection Method on the collection confirmation screen and select Yes .
  • Page 17: Filter Maintenance

    Filter Maintenance • The filter of the product is a disposable item, and requires periodic inspection and maintenance. ( ) Estimated standard operating hours: 2,500 hours/year Inspection cycle: 1 year Replacement cycle: 5 years If the operating hours exceed the above estimated standard operating hours (2,500 hours/year): 15 hours/day x 365 days in operation (5,475 hours/year), the filter would need to be replaced sooner. The product may require maintenance (i.e., filter cleaning or replacement) in one- to two-year intervals. Use the above information for reference. Keep in mind that the above replacement intervals do not indicate the guarantee period of the filter. • For filter inspection or replacement in detail, consult your dealer. 3P225748-4G English...
  • Page 18: Useful Information

    Useful Information Troubleshooting The following symptoms are not signs of malfunctions. Symptom Probable cause Slight clicking noise is generated. The driving sound of the air filter. Scorching noise is generated. The driving sound of the brush. The “ ” is displayed or the AUTO CLN The product is performing filter FILTER The fan automatically turns. indicator on the panel is flashing auto-cleaning and transferring dust. green (*). The product blows out air The louver automatically moves. horizontally during filter auto- cleaning.
  • Page 19 „Contact your dealer in the following cases • When the air conditioner is malfunctioning (e.g., giving off a burning odor), stop the air conditioner and turn off power. Continued operation under such circumstances may result in failure, electric shocks, or fire. Contact your dealer. Measures to be taken before requesting Symptom servicing The fuse blows out or safety devices, such as the power circuit breaker and ground leakage circuit interrupter trip Do not turn on the product. often. The operation of the buttons on the remote controller is Turn off the product.
  • Page 20 Optional accessory Dedicated parts are prepared so that customers can use a wide range of air conditioner functions. Specify Daikin genuine products at the time of purchasing the parts. For details, contact your dealer. Replacement optional accessory Optional accessory L-shaped extension pipe KKHAP55A160 Replacement filter KAFP554A160 Connecting pipe...
  • Page 21 „Advise the repairer of the following items • Model name • Date of installation • Failure conditions: As precise as possible. • Your address, name, and telephone number „Repairs after Expiration of Cost-free Guarantee Repair Period Contact your dealer. Daikin will conduct paid repairs if the product is repairable with its functions maintained. „Stock Period of Performance Spare Parts Performance spare parts are components that are required to maintain the function of the product. Daikin has a stock of performance spare parts for the air conditioner for nine years after the stoppage of producing the air conditioner. „Recommendation for Maintenance Inspection Contract The interior of the air conditioner will become dirty with its performance degraded if the air conditioner is used for several seasons.
  • Page 22 For details, contact your dealer. „Rough Standards for Part Replacement Frequency [Keep in mind that the replacement frequency does not indicate the guaranteed operating period of the part.] • Table 2. Replacement frequency Main part name Inspection period Replacement frequency Filter 1 year 5 years Note: 1. This table shows main parts. For details, refer to the maintenance inspection contract. 2. T he replacement frequency indicates a rough period required until the replacement of the part becomes necessary. Make use of the table for appropriate maintenance designing (e.g., the budgeting of part replacement cost). 3. R egular inspection is required, depending on the installation environment. For details, contact your dealer. Furthermore, the overhauling or internal cleaning of the product conducted by technicians other than those authorized by Daikin may not be within the scope of Daikin’s product guarantee term. 3P225748-4G English...
  • Page 23 Useful Information „Relocation Contact your dealer because the same requires a specialized technique in the case of relocating and reinstalling the air conditioner for some reason, e.g., the movement of the site. „Inquiry Contact your dealer for after-sale services. 3P225748-4G English...
  • Page 24 5151 San Felipe, Suite 500 Houston, TX 77056 3P225748-4G EM13A020A [1506] FS...