I N S T A L L A T I O N
Gas cooktops only:
Install gas cooktop seal kit
(purchase separately)
Available for application with gas cooktops - where proper sealing is required
and holes are required in cabinet base. Kit includes trim seal, toe-kick cover
plate, and cabinet hole cover plate.
Installation instructions are included with the gas cooktop seal kit.
Install roof cap, wall cap, inline or remote
blower
1. Follow instructions included with caps, inline and remote blower.

Connect ductwork

1. From roof cap, wall cap, or remote blower - work back towards the
cabinet, attaching all ductwork, elbows and transitions as previously
planned.
2. Connect ductwork (and transition, if required) to lex blower or downdraft.
If necessary, use (2) #8-18 x .375 (9.5mm) Phillips screws for transition.
Note: Regardless of blower placement/exhaust, ensure that all seams are
properly taped - to make them secure and air-tight. This includes seams/
gaps between panels and/or on the blower.
Install the electrical panel
(if previously removed from downdraft housing)
1. If electrical panel was removed from the downdraft housing in order to
mount it in a remote location: Mount electrical panel in chosen location.
Note: Do not mount electrical panel with slots in cover facing downward.
Page 18
Plan house wiring
WARNING
RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges. The connection
cable can be damaged. Do not bend or pinch connection cables
during installation.
Before connecting the appliance, check the house wiring to make sure
it has suficient circuit protection. The voltage and frequency of the
appliance must match the electrical installation (see rating plate).
Only a qualiied electrician who takes the appropriate regulations into
account may lay or replace the connecting cable.
Follow all valid standards and laws.
Ensure that the electrical connection meets the requirements of the
latest version of all applicable standards and laws in the appropriate
country, especially the following standards:
National Electrical Code, ANSI/ NFPA 70*, or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No.0-M91**, UL 507.
Have a qualiied electrical technician check the grounding of the
appliance.
Do not ground to a gas line.
Keep these installation instructions for future reference.
Ensure that the wire diameter meets the requirements of the latest
version of all applicable standards and laws in the appropriate country,
especially the following standards:
National Electrical Code, ANSI/NFPA 70*, or CSA Standards C22.1-
94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91**.
The downdraft with the Flex Blower (purchase separately) draws 3.0
Amps and requires a 120 VAC, 60 Hz circuit.
The downdraft with Remote Blower (purchase separately) draws 9.0
Amps (max.) and requires a 120 VAC, 60 Hz circuit.
The downdraft has a 30-in. (762mm). long power cord with a 3-pronged
plug. Plan to provide a grounded outlet in a location which will allow the
power cord to reach.