L M T S E R I E S | M A G N E TO S T R I C T I V E L E V E L T R A N S M I T T E R L M T 1 0 0 & 2 0 0 M O D E L S | C I/ L M T 1 0 0/ 2 0 0 - E N R E V. B
Specifications (Refer to LMT100/200 Datasheets for Details)
Electronic transmitter:
Repeatability
Non-linearity
Measuring accuracy
Supply voltage
Output/Communications
User Interface
Power consumption
Ambient temperature
Humidity
Electrical connection
Ingress protection
Sensor tube:
Material
Process temperature
Process pressure
Probe length
Figure 3 LMT General Model
± 0.005% of Full Scale or 0.305 mm (0.012 in), whichever is greater
± 0.01% of Full Scale or 0.864 mm (0.034in), whichever is greater
± 0.01% of Full Scale or 1.27 mm (0.050 in), whichever is greater
12 to 42 Vdc - 4-20mA HART loop powered
4-20mA HART7®
Interactive display, DTM, EDDL with NE107 messaging
4-20mA
HART mode (4.0mA)
-40 to 85°C (-40 to 185°F) Ambient
0 to 100% RH
Two M20 x 1.5 or two 1/2in. FNPT, adapters and bus connectors also available
IP66, NEMA 4X
316/L Stainless Steel
LMT100: -195.5 to 121.1°C (-320 to 250°F)
LMT100: -1.0 to 124.1 bar @ 149°C (-14.7 to 1800 psig @ 300°F)
LMT100: 304.8mm to 9.14m (1 to 30ft) / LMT200: 304.8mm to 15.24m (1 to 50ft)
Compression
Fitting Option
PL - Probe length depends
on process temperature
No minimum
float separation
Lowest
measurable level
at 36.0 Vdc - 3.6mA 0.13 watts; 21mA 0.76 watts
at 12.0 Vdc - 3.6mA 0.043 watts; 21mA 0.25 watts
at 36.0 Vdc 0.144 watts
at 12.0 Vdc 0.048 watts
6 in. (152.4mm) minimum
See dimensional drawings
Top of vessel
L1 = Unmeasured
Highest
measurable
level
IL - Insertion length
distance from bottom of
process connection to the
ML
end of the probe
L2 = Unmeasured