Elmdene INT600 Manual

Internal sounder with hi/lo feature

Advertisement

Quick Links

Elmdene International Ltd
3 Keel Close, Interchange Park,
Portsmouth, Hampshire, PO3 5QD, UK
INT600/INT600S Internal Sounder
Note: This unit NOT suitable for external installation
EN50131-4: 2009
Power Source
Security Grade
Environmental Class
F
EATURES
108dB(A) siren output
-
Independent low volume E/E, Keypad output
-
12V dc voltage operation
-
Polycarbonate cover and backplate
-
2 way tamper protection: cover, rear
-
O
PERATION
The INT600 sounder is used for notification of an alarm condition and entry/exit tone as generated within
an intruder, hold-up or other alarm system. In response to appropriate commands from the control panel,
the INT600 will emit a high intensity sound for alarm and an adjustable low level tone for
entry/exit/keypad.
The INT600 will detect any attempt to gain unauthorised access to the sounder by removal of the cover, or
any attempt to remove it away from its mounting surface. This will generate a tamper signal which is
normally fed back to the alarm control panel
The INT600 is classified as an internal remote powered sounder and is powered via an external power
source.
The INT600S is classified as an internal self powered sounder and has an on-board battery which is
recharged via the external power source. This battery is used to operate the sounder if the external power
to the sounder is removed.
F
I
UNCTIONAL
NFORMATION
T
C
AMPER
IRCUIT
Volt free tamper terminals 'TS & TR' open when front or rear tamper switch is open, or on loss of H+ or H-.
INT600
Remote
3
II
Volt Free Tamper Connection
-
Hold-off supply failure detection
-
Selectable sound auto cut-off timer
-
Full SAB using internal battery (INT600S)
-
Tel: +44(0)23 9269 6638
Fax: +44(0)23 9266 0483
Web:
www.elmdene.co.uk
with Hi/Lo Feature
INT600S
Self Powered
2
II

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INT600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Elmdene INT600

  • Page 1 INT600 will emit a high intensity sound for alarm and an adjustable low level tone for entry/exit/keypad. The INT600 will detect any attempt to gain unauthorised access to the sounder by removal of the cover, or any attempt to remove it away from its mounting surface. This will generate a tamper signal which is...
  • Page 2 M- R- H+ H- TR TS BT+ BT- Figure 1. Connections and Timer Selection Jumper With the cut-off timer link NOT fitted, the INT600(S) sounder will automatically stop sounding after 15 minutes, irrespective of the status of the sound trigger (R-) input.
  • Page 3 IMPORTANT: Ensure correct polarity of connections and that exposed battery leads DO NOT accidentally touch. Dispose of used batteries in accordance with all national and local regulations Technical Support: +44(0)23 9269 6638 (option 3) PAK200035_07A Oct 2014 ©2014 ELMDENE INTERNATIONAL LTD...
  • Page 4 Environmental Class II This product is suitable for use in systems designed to comply with PD6662:2010 at: Grade 2 (INT600S) or Grade 3 (INT600) and Environmental Class II. The packaging supplied with this product may be recycled. Please dispose of packaging accordingly.

This manual is also suitable for:

Int600s

Table of Contents