2.4
Charger Unit BC-6158-SS
According to the battery used, set the output voltage of the charger unit to 26.7 VDC (default set-
ting) or 28 VDC. This section shows how to change the output voltage from 26.7 VDC to 28 VDC.
Valve-regulated lead-acid battery, maintenance free
Flooded lead-acid battery
1. Remove four bolts to remove the panel at the bottom of the rack console.
Charger Unit
BC-6158-SS
2. Pull the charger unit to switch the toggle switch to 28 VDC. The toggle switch is on the
05P0659 board located on the side of the charger unit.
Charger Unit
BC-6158-SS
3. Replace the charger unit.
2-8
Battery
Bolt
Bolt
Output Voltage
26.7 VDC (default)
28 VDC
Toggle Switch
05P0659 Board