Deleting, Replacing or Editing Wireless Keys
Use the following procedure to delete, replace, or change any of the programming for a wireless key.
Step
Action
1
Enter the program mode by pressing the [1] and [3] keys
simultaneously for a few seconds within 30 seconds of applying
power.
Enter [5] (Wireless Key Editing). Enter the device number for the
2
wireless key you desire to edit. This must be a device that has its
serial number programmed in the 6128RF already.
To delete the serial number, press [✳] then press [9], then press [✳]
again.
To exit without deleting the serial number, press the [#] key
Press the [✳] key to continue.
To change any of the programming for the wireless key, perform the
3
following step(s) in the Programming for an Installation WITH
Local Wireless Keys.
For the user code, perform step 5
For the loop functions, perform steps 6 and 7.
For the on-board relay assignment, perform steps 8 to 9.
4
When you have completed editing the wireless keys, press the [✳]
key twice to exit the program mode.
Note: Upon exiting of the Program Mode, the 6128RF will alternately flash "Ad," the 2-digit keypad address,
and the 2-digit receiver address. If the either of these is incorrect, repeat steps 1 through 3 under Programming
for an Installation Without Local Wireless Keys.

Troubleshooting

The following error messages will cause the 6128RF to produce rapid beeps for 5 seconds. The table below
describes the error messages and the corrective actions.
Display
Probable Cause
Lb
Low battery in the wireless
key
OC
Open circuit
1C
Incompatible connection
Check 09
1.
2.

Specifications

Physical:
4-3/4" H x 5-3/4" W x 1" D (121mm x
146mm x 25.4mm)
Wiring:
(+)
(-)
DO
DI
Range:
200' nominal
6128RF Receiver is not
communicating
Another device on the
keypad terminals is
not communicating to
the control panel
+12VDC
Ground
Data to Control Panel
Data from Control Panel
Corrective Action
1.
Replace the battery if the wireless key has a replaceable
battery.
2.
Replace the transmitter if the wireless key does not have a
replaceable battery.
Verify the Data Out (DO) wire is connected properly.
Verify that the control panel is not a First Alert type control
panel.
1.
Verify the Data In (DI) wire is connected properly.
2.
Verify the wiring between the control and all other devices.
Frequency 345 MHz
Current:
Standby
Transmitting and/or
Relay Activated
Relay:
Normally Open, 1A, 28VDC
Sounder:
Piezo-electric (fire alarm is loud pulsing
tone; burglary/audible panic alarm is
continuous tone)
Display
Alternately flashes "oo" and
two dashes.
Flashes the device number
and a hyphen.
Once the device number is
entered, alternately flashes
"d" with the device number
and the serial number.
Alternately flashes "d" with
the device number and "--."
90ma