SAFETY Safety is always a priority at Ranger Tugs. Please read all manuals to ensure that equipment is used in a safe manner. We highly recommend attendance in a Coast Guard approved boating safety course. Such courses are available from the Coast Guard directly or from boating organizations.
SYMBOL GLOSSARY Attention! – Important Operating or Maintenance Instructions Attention! – Electrical Shock Hazard Fresh Water Black Water Fuel Standard Equipment Optional Equipment Hints...
SPECIFICATIONS R-27 Length ..................27’ 0” 8.2 m Length Overall – motor up ............34’ 6’’ 10.5 m – motor down ............32’ 9’’ 10 m Length Overall on Trailer – motor up ..........40’ 7’’ 12.4 m – motor down ........38’ 8’’...
PORT FIT TINGS 1 2 3 4 5 6 7 8 9 14 10 11 12 13 15 Keep all vents, drains and exhausts clear of any obstructions to ensure proper performance of each system. ➎ ➍ ➌ ➓ ➏ ➐ ➊...
FUEL SYSTEM, ENGINE, GENERATOR Yamaha 300 There is a secondary on-engine fuel filter that is not shown on this drawing. You will be able to find information about this filter in the engine manual supplied with your boat. Fuel vent Fuel fill Fuel vent Vent filter...
RAW WATER / SEA STRAINER SYSTEM • Multi port sea strainer for head and raw water wash down pump. • A/C Raw Water Input • Generator raw water thru-hull strainer R-27 LE R-27 NW Head Raw Water Head Raw Water...
FRESH WATER PLUMBING SYSTEM 40 Gallon Fresh Water Tank, 5.3 Gallon Hot Water Heater, 3.5 GPM Fresh Water Pump. Water vent Head Cabin sink sink Water fill Water Pump Sender Water heater Cockpit sink Transom shower H-23 7/14 Disinfecting The Fresh Water System APPENDIX - POTABLE WATER SYSTEMS The information contained in this appendix provides supplementary data about disinfecting a potable water system.
SHOWER SUMP 12V, 800 GPH (This should be inspected for debris on a regular basis if shower is used frequently.) The shower sump box is located underneath the removable v-berth step positioned just outside the head door. Depth Transducer Forward Bilge pump Shower drain Sump pump Aft AC condensate drain...
BILGE PUMP SYSTEM 12V 1100GPH (Aft & Center) 12V 900GPH (Forward) The bilge pumps operate automatically by checking for water every 2.5 minutes even with battery switches and breakers in the OFF position. However, the BILGE PUMP and BILGE PUMP2 will run continuously once their switches are placed in the on position.
WASTE SYSTEM WITH MACERATOR PUMP 30 Gallon Tank with standard pump out, and vent Macerator pump out Waste tank pump out stations are widely available. Please follow the directions carefully for the pump out equipment you are using to avoid damage to the waste system.
AIR CONDITIONING A/C Vent Main Cabin A/C Unit (Under Helm Seat) Main Cabin A/C Air Intake Grill (keep uncovered) Main Cabin A/C Control Panel (in Mid-Berth) A/C Raw Water Pump Thru Hull/Valve Sea Strainer...
WEBASTO FURNACE Webasto furnace is located under helm seat. The control panel is located at the quarter berth power management center. The fuel pump is beneath the galley sink, inside of the black box. V-Berth Interior Heat Vent Air Intake Webasto Furnace Exhaust (keep unblocked/...
SOLAR PANEL Solar panel 145 watt, with display panel • The solar panel is designed to provide charging to the house & engine batteries. 90% of its charge is dedicated to the house battery and 10% is dedicated to the engine battery. •...
BAT TERY CONFIGURATION 2 House Batteries, 1 Engine Battery, 1 Thruster Battery. House, engine, & battery parallel switches are located in the midberth. Thruster battery switch is located in the port side lazarette Inverter battery switch is located in the port side lazarette Once the EMERGENCY PARALLEL switch is placed in the on position the power from the HOUSE batteries will be transferred to the ENGINE battery.
FUSE LOCATION & VALUES FUSE LOCATION & VALUES These DC fuse blocks and windlass breaker are located behind a hinged access panel on the star- board side in the head behind the mirror. Fuses are automotive blade type and all values shown below are in Amps.
FUSE LOCATION & VALUES These DC fuse blocks are located behind the wood hatch in the midberth. Fuses are automotive blade type and all values shown below are in Amps. HOUSE BREAKER This fuse block is always hot...
AC DISTRIBUTION PANEL & ROTARY SWITCH AC Distribution Panel AC Rotary Selector Switch (Available with Generator) AC Main Line 2 (with AC) A/C Main 1 and battery charger breaker must on in order for batteries to charge. The AC Rotary Switch Selector Switch will determine which source of incoming 120 Volt power to use for your AC Distribution Panel.
12V HELM CONTROL OPERATION Armed = Red light/audible alarm Off = Red light only. The bilge pumps operate automatically with electronic float switches regardless of battery switch position. However, the BILGE PUMP and BILGE PUMP2 will run continuously once their switches are placed in the on position.
RANGER TUG R-27 WIRING SCHEMATIC (P.D.P.) R-27 Power Distribution ELECTRICAL SCHEMATIC To generator control panel. 6 red Fuse Block A. 175A HOUSE 1/O red To A.C. panel. 2 red 2 red 6 red Fuse Block B. SWITCH 6 red Windlass Breaker.
CARE AND MAINTENANCE The following checklists are examples and are not all inclusive and are provided only as a guide. Please customize to your personal needs. Consult your engine and trailer user manuals for ad- ditional information. EXAMPLE OF A PREPARATION FOR THE ROAD CHECKLIST TOW VEHICLE –...
EXAMPLE OF A SPRING PRE-LAUNCH CHECKLIST CLEANING Remove debris from scuppers and scupper drains. £ Clean hull using a mild biodegradable detergent and then wax. £ Clean topsides and decks using a mild biodegradable detergent and then wax. £ Clean and polish all bright work. £...
EXAMPLE OF WINTER STORAGE CHECKLIST GENERAL MAINTENANCE Fill Fuel Tank and add a fuel stabilizer. £ Empty and clean black water tank. £ Empty fresh water tank use a non-toxic antifreeze per manufacturer’s directions, £ or remove all water from the system. Winterize black and fresh water tanks as necessary based on weather.
All rights reserved. Reproduction or translation by any means in whole or in part is not permitted without written authorization from Ranger Tugs. The information contained herein is correct to the best of Ranger Tugs knowledge and the contents may change without notice and without incurring obligation.