  • Page 1 R-27 Owner’s Manual Quality Craftsmanship Since 1958...
  • Page 2: Table Of Contents

    Ac Distribution Panel & Rotary Switch ..............22 12V Helm Control Operation ................. 23 Ranger Tug R-27 Wiring Schematic (Acc. 1) ............24 Ranger Tug R-27 Wiring Schematic (Acc. 2) ............25 Ranger Tug R-27 Wiring Schematic (Acc. 3) ............26 Ranger Tug R-27 Wiring Schematic (Lighting) ............
  • Page 3: Congratulations

    SAFETY Safety is always a priority at Ranger Tugs. Please read all manuals to ensure that equipment is used in a safe manner. We highly recommend attendance in a Coast Guard approved boating safety course. Such courses are available from the Coast Guard directly or from boating organizations.
  • Page 4: Symbol Glossary

    SYMBOL GLOSSARY  Attention! – Important Operating or Maintenance Instructions  Attention! – Electrical Shock Hazard Fresh Water Black Water Fuel Standard Equipment Optional Equipment  Hints...
  • Page 5: Specifications (Subject To Change Without Notice)

    SPECIFICATIONS R-27 Length ..................27’ 0” 8.2 m Length Overall – motor up ............34’ 6’’ 10.5 m – motor down ............32’ 9’’ 10 m Length Overall on Trailer – motor up ..........40’ 7’’ 12.4 m – motor down ........38’ 8’’...
  • Page 6: Equipment Location

    EQUIPMENT LOCATION STARBOARD FIT TINGS 1 2 3 7 8 11 12 13 14 15 16 17 18 19 4 5 6 9 10 Keep all vents, drains and exhausts clear of any obstructions to ensure proper performance of each system. ➐...
  • Page 7: Port Fittings

    PORT FIT TINGS 1 2 3 4 5 6 7 8 9 14 10 11 12 13 15 Keep all vents, drains and exhausts clear of any obstructions to ensure proper performance of each system. ➎ ➍ ➌ ➓ ➏ ➐ ➊...
  • Page 8: Stern Components

    STERN COMPONENTS 1 2 3 4 5 6 7 8 9 10 11 ➊ ➌ ➋ ➍ ➍ ➐ ➏ ➎ ➎ ➏ ➐ ➑ ➑ ➓ ➓ ➒ ➒ ➊ ➐ Ski Post Trailer Turn/Brake Lights ➋ ➑ Pullout Fresh Water Shower Cockpit Scupper Drains ➌...
  • Page 9: Main Cabin And Cockpit Lights

    MAIN CABIN AND COCKPIT LIGHTS...
  • Page 10: Fuel System, Engine, Generator

    FUEL SYSTEM, ENGINE, GENERATOR Yamaha 300 There is a secondary on-engine fuel filter that is not shown on this drawing. You will be able to find information about this filter in the engine manual supplied with your boat. Fuel vent Fuel fill Fuel vent Vent filter...
  • Page 11: Raw Water / Sea Strainer System

    RAW WATER / SEA STRAINER SYSTEM • Multi port sea strainer for head and raw water wash down pump. • A/C Raw Water Input • Generator raw water thru-hull strainer R-27 LE R-27 NW Head Raw Water Head Raw Water...
  • Page 12: Fresh Water Plumbing System

    FRESH WATER PLUMBING SYSTEM 40 Gallon Fresh Water Tank, 5.3 Gallon Hot Water Heater, 3.5 GPM Fresh Water Pump. Water vent Head Cabin sink sink Water fill Water Pump Sender Water heater Cockpit sink Transom shower H-23 7/14 Disinfecting The Fresh Water System APPENDIX - POTABLE WATER SYSTEMS The information contained in this appendix provides supplementary data about disinfecting a potable water system.
  • Page 13: Shower Sump

    SHOWER SUMP 12V, 800 GPH (This should be inspected for debris on a regular basis if shower is used frequently.) The shower sump box is located underneath the removable v-berth step positioned just outside the head door. Depth Transducer Forward Bilge pump Shower drain Sump pump Aft AC condensate drain...
  • Page 14: Bilge Pump System

    BILGE PUMP SYSTEM 12V 1100GPH (Aft & Center) 12V 900GPH (Forward) The bilge pumps operate automatically by checking for water every 2.5 minutes even with battery switches and breakers in the OFF position. However, the BILGE PUMP and BILGE PUMP2 will run continuously once their switches are placed in the on position.
  • Page 15: Waste System With Macerator Pump

    WASTE SYSTEM WITH MACERATOR PUMP 30 Gallon Tank with standard pump out, and vent Macerator pump out Waste tank pump out stations are widely available. Please follow the directions carefully for the pump out equipment you are using to avoid damage to the waste system.
  • Page 16: Air Conditioning

    AIR CONDITIONING A/C Vent Main Cabin A/C Unit (Under Helm Seat) Main Cabin A/C Air Intake Grill (keep uncovered) Main Cabin A/C Control Panel (in Mid-Berth) A/C Raw Water Pump Thru Hull/Valve Sea Strainer...
  • Page 17: Webasto Furnace

    WEBASTO FURNACE Webasto furnace is located under helm seat. The control panel is located at the quarter berth power management center. The fuel pump is beneath the galley sink, inside of the black box. V-Berth Interior Heat Vent Air Intake Webasto Furnace Exhaust (keep unblocked/...
  • Page 18: Solar Panel

    SOLAR PANEL Solar panel 145 watt, with display panel • The solar panel is designed to provide charging to the house & engine batteries. 90% of its charge is dedicated to the house battery and 10% is dedicated to the engine battery. •...
  • Page 19: Battery Configuration

    BAT TERY CONFIGURATION 2 House Batteries, 1 Engine Battery, 1 Thruster Battery. House, engine, & battery parallel switches are located in the midberth. Thruster battery switch is located in the port side lazarette Inverter battery switch is located in the port side lazarette Once the EMERGENCY PARALLEL switch is placed in the on position the power from the HOUSE batteries will be transferred to the ENGINE battery.
  • Page 20: Fuse Location & Values

    FUSE LOCATION & VALUES FUSE LOCATION & VALUES These DC fuse blocks and windlass breaker are located behind a hinged access panel on the star- board side in the head behind the mirror. Fuses are automotive blade type and all values shown below are in Amps.
  • Page 21: Fuse Location & Values

    FUSE LOCATION & VALUES These DC fuse blocks are located behind the wood hatch in the midberth. Fuses are automotive blade type and all values shown below are in Amps. HOUSE BREAKER This fuse block is always hot...
  • Page 22: Ac Distribution Panel & Rotary Switch

    AC DISTRIBUTION PANEL & ROTARY SWITCH AC Distribution Panel AC Rotary Selector Switch (Available with Generator) AC Main Line 2 (with AC) A/C Main 1 and battery charger breaker must on in order for batteries to charge. The AC Rotary Switch Selector Switch will determine which source of incoming 120 Volt power to use for your AC Distribution Panel.
  • Page 23: 12V Helm Control Operation

    12V HELM CONTROL OPERATION Armed = Red light/audible alarm Off = Red light only. The bilge pumps operate automatically with electronic float switches regardless of battery switch position. However, the BILGE PUMP and BILGE PUMP2 will run continuously once their switches are placed in the on position.
  • Page 24: Ranger Tug R-27 Wiring Schematic (Acc. 1)

    RANGER TUG R-27 WIRING SCHEMATIC (ACC. 1) R-27 Accessories 1 ELECTRICAL SCHEMATIC +12V -12V Helm Fuse Block B Bilge BRN 16 To Bilge Pump Bow Pump Bow PUR/WHT 16 YEL 16 Defrost Fans Macerator BRN 10 YEL 10 Pump 30A RED 10...
  • Page 25: Ranger Tug R-27 Wiring Schematic (Acc. 2)

    RANGER TUG R-27 WIRING SCHEMATIC (ACC. 2) R-27 Accessories 2 ELECTRICAL SCHEMATIC -12V +12V Fuse Block A 12V Outlet ORG/WHT 10 YEL 10 Dash 12V Outlet RED/PUR 10 YEL 10 Quarter- Berth ORG/WHT 10 YEL 10 12V Outlet Bathroom Bathroom...
  • Page 26: Ranger Tug R-27 Wiring Schematic (Acc. 3)

    RANGER TUG R-27 WIRING SCHEMATIC (ACC. 3) R-27 Accessories 3 -12V +12V ELECTRICAL SCHEMATIC 24/7 Fuse Block D Stove ORG/BLK 16 YEL 16 Stove - see MFR Schematic Switch YEL 16 To Propane Sensor B.P. WHT/ORG 16 To Propane Sensor YEL 16 To Acc.
  • Page 27: Ranger Tug R-27 Wiring Schematic (Lighting)

    RANGER TUG R-27 WIRING SCHEMATIC (LIGHTING) R-27 Lighting ELECTRICAL SCHEMATIC -12V +12V Dash Fuse Block B RED 10 Bilge Pump (Bow) To Acc. #1 Schematic Subpanel RED 10 Macerator 8 Switch To Acc. #1 Schematic (Helm) RED 10 Defrost Fans To Acc.
  • Page 28: Ranger Tug R-27 Wiring Schematic (P.d.p.)

    RANGER TUG R-27 WIRING SCHEMATIC (P.D.P.) R-27 Power Distribution ELECTRICAL SCHEMATIC To generator control panel. 6 red Fuse Block A. 175A HOUSE 1/O red To A.C. panel. 2 red 2 red 6 red Fuse Block B. SWITCH 6 red Windlass Breaker.
  • Page 29: Ranger Tug R-27 Working Deck

    RANGER TUG R-27 WORKING DECK...
  • Page 30: Care And Maintenance

    CARE AND MAINTENANCE The following checklists are examples and are not all inclusive and are provided only as a guide. Please customize to your personal needs. Consult your engine and trailer user manuals for ad- ditional information. EXAMPLE OF A PREPARATION FOR THE ROAD CHECKLIST TOW VEHICLE –...
  • Page 31: Example Of A Spring Pre-Launch Checklist

    EXAMPLE OF A SPRING PRE-LAUNCH CHECKLIST CLEANING Remove debris from scuppers and scupper drains. £ Clean hull using a mild biodegradable detergent and then wax. £ Clean topsides and decks using a mild biodegradable detergent and then wax. £ Clean and polish all bright work. £...
  • Page 32: Example Of Winter Storage Checklist

    EXAMPLE OF WINTER STORAGE CHECKLIST GENERAL MAINTENANCE Fill Fuel Tank and add a fuel stabilizer. £ Empty and clean black water tank. £ Empty fresh water tank use a non-toxic antifreeze per manufacturer’s directions, £ or remove all water from the system. Winterize black and fresh water tanks as necessary based on weather.
  • Page 33 NOTES...
  • Page 34 NOTES...
  • Page 35 NOTES...
  • Page 36: Contacts

    All rights reserved. Reproduction or translation by any means in whole or in part is not permitted without written authorization from Ranger Tugs. The information contained herein is correct to the best of Ranger Tugs knowledge and the contents may change without notice and without incurring obligation.

Table of Contents