Steamer
625-MCD & MFY
Stores that want to install two steamers will need to use the T-Connect Kit. the T-Connect Kit connects the inlet water line to both the steamers.
Connect the shorter end of T-Connect to the steamer whose
1
regulator is closest to the inlet water line. T-Connect's female
end to steamer's male end.
Place the long end of the T-Connect tubing in between the two
2
steamers.
Printed in U.S.A. 1/06 © 2006
Connection of Two Steamers
To Steamer Closest to Inlet Water
Line
To Steamer Farthest from Inlet
Water Line
To Inlet Water Line
14
Connect the longer end of T-Connect to the steamer whose
3
regulator is farthest from the inlet water line. T-Connect's female
end to steamer's male end.
Connect the inlet water line's female end to the T-Connect's male
4
fitting. The two steamers have been connected to the inlet water
line. Set both steamers' regulators to 25 psi.