Stores that have harder water in their areas may experience scale buildup in their water tubes, thus clogging the tube and preventing water from being
dispensed into the steaming chamber. If the tube needs to be replaced, this sheet will illustrate how to replace the water tube.
First, turn off and unplug steamer. Let steamer cool down. To
1
remove the rear cover plate that shields the water tube, use a
Phillips head screwdriver to remove the two screws. Next, take
off the rear cover plate to access the water tube.
To pull the tube out from the water valve, push in the grey disk on
2
the water valve and then slowly slide the tube from the water
valve.
Grey disk is here —
at end of valve
Using pliers, gently pull the tube out from the platen. You may
3
need to softly rock it back and forth. Replace the black insulating
bushing if the original bushing pulled out with the water tube. All
units must have a bushing installed. To reinstall the bushing,
lubricate it with water and push it back into the opening.
Platen must be cool.
625-505revI-EN
Water Tube Replacement
CAUTION
To insert the new tube, first insert the top end through the hole
4
that leads to the platen. The tube will fit through the insulating
bushing.
Push the other end of the tube into the water valve. Ensure that
5
you feel it click into place. Gently tug on the water tube to check if
it is secure. If the tube slides out, reinstall the tube. If tube is
improperly installed, water will leak at this point.
Finally, reinstall the rear cover plate. Turn on unit and begin a
6
water cycle to check for leaking at the water valve. If leaking
occurs at the back panel of the steamer, turn off unit and repeat
Step 5.