Terminal Block (Relay Output Mode); Blue Led Indicator - Algo 8180 User Manual

Sip audio alerter (g2)
Hide thumbs Also See for 8180:
Table of Contents

Advertisement

Note: See "Additional Features Tab – Input/Output" section of this user doc for
additional information on input device configuration

Terminal Block (Relay Output Mode)

By default, these output terminals (Normally Open) are inactive. Outputs can be
connected to the "Dry Contact Relay" Terminal Block (terminals 5 & 6), which provide
contact closure when the 8180 SIP Audio Alerter (G2) is active from one of the following
events: Ring, Page, Both, or disabled. The relay can trigger an external light or other
device when specified event occurs.

Blue LED Indicator

This LED light is on during initialization, boot, or while active. Ring and Page modes, when
active, will turn the LED on steady. If the optional Talkback mode, 'Two-way', is enabled,
under Basic Settings > Page Mode, the LED will now flash instead (during a page event)
Document 90-00095A
01/24/2019
Page 59
Algo Communication Products Ltd
4500 Beedie St Burnaby BC Canada V5J 5L2
www.algosolutions.com
8180 SIP Audio Alerter (G2) FW 1.7
(604) 454-3792