Download Print this page

Advertisement

Quick Links

DESIGN FEATURES
Housing:
Phenolic
Pump Rotor: Phenolic
Elastomers: NBR, EPDM, FPM
Shaft:
Carbon steel
Bearings:
Prelubricated, fully sealed ball bearings
mounted on shaft and
integrally cast in pump body.
Seal:
Mechanical (carbon/ceramic)
Mounting:
Resilient mountings for quiet operation
Port Size:
1" OD for hose connections
INSTALLATION
Mounting Position.
position. When mounting vertically, it is necessary to keep
bearings above seals to prevent possible seal leakage into
bearings.
Pre-Wetting.
Prior to connecting pump, wet pump
elements and mechanical seal by adding fluid to be
pumped into suction and discharge ports. Turn shaft over
several times in a counterclockwise direction to work fluid
into elements.
Piping.
Install 1" ID hose using adjustable hose clamps. If
hose is lengthy, it should be supported to avoid excessive
strain on pump housings.
Drive.
On belt driven units, adjust belt tension to point of
non-slip. Do not overtighten.
On direct drive units, coupling components should be
aligned and spaced at least
Note: Pump shaft diameter is .6267". Pulley or coupling
may have to be hand reamed for proper fit.
Check rotation before startup. Rotation must be
counterclockwise when facing shaft to prevent rotor
unscrewing from shaft.
Maximum speed is 1750 rpm.
OPERATION
Self-Priming. With wetted pumping elements, the pump is
capable of 25 feet of suction lift when operating at 1750
rpm with hose size equal to port size. Be sure suction lines
are air tight or pump will not prime.
DO NOT RUN DRY. Unit depends on liquid pumped for
lubrication. For proper lubrication, flow rate should be at
least 10% of rated capacity at a given rpm.
Pressure and Temperature Limits. Maximum discharge
pressure is 25 psig. Unit is suitable for service at
temperatures shown in Table 1.
SERVICE MANUAL
MOYNO
300 SERIES
30100, 30102, 30104, AND 30105 MODELS
Pump may be mounted in any
1
/
" apart.
16
®
500 PUMPS
Storage.
periods by removing suction and discharge lines, loosening
resilient mount clamps and turning discharge port to drain
position.
Elastomer
*NBR
*EPDM
*FPM
*NBR = Nitrile
*EPDM = Ethylene-Propylene-Diene Terpolymer
*FPM = Fluoroelastomer
TROUBLE SHOOTING
WARNING: Before
Failure To Pump.
1.
Belt or coupling slip: Adjust belt tension or tighten set screw
on coupling.
2.
Stator torn; possibly excessive pressure: Replace stator,
check pressure at discharge port.
3.
Wrong rotation: Rotation must be counterclockwise when
facing shaft.
4.
Threads in rotor or on shaft stripped: Replace part. Check
for proper rotation.
5.
Excessive suction lift or vacuum
Section:
MOYNO
Page: 1 of 4
Date:
Always drain pump for extended storage
Table 1. Temperature Limits
Temperature Limits
10°-160°F
10°-210°F
10°-240°F
making
adjustments,
power source and thoroughly bleed pressure
from system. Failure to do so could result in
electric
shock
or
serious
Replace belt or coupling guards before re-
connecting power.
.
®
500 PUMPS
March 1, 1998
disconnect
bodily
harm.

Advertisement

loading
Need help?

Need help?

Do you have a question about the 300 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for moyno 300 SERIES

  • Page 1 MOYNO 500 PUMPS Page: 1 of 4 Date: March 1, 1998 SERVICE MANUAL ® MOYNO 500 PUMPS 300 SERIES 30100, 30102, 30104, AND 30105 MODELS DESIGN FEATURES Housing: Phenolic Pump Rotor: Phenolic Elastomers: NBR, EPDM, FPM Shaft: Carbon steel Bearings:...
  • Page 2: Pump Disassembly

    Page 2 Pump Overloads. Excessive discharge pressure: Check discharge pressure Remove screws (112) which secure suction housing (2) for 25 psig maximum or obstruction in discharge line. to pump body (1). Remove suction housing (2) and stator (21). Fluid viscosity too high: Limit fluid viscosity to 20,000 CP or 100,000 SSU.
  • Page 3: Parts List

    Page 3 When ordering parts, please specify pump model number, pump serial number, part number, part description and quantity. PARTS LIST Item No. Description Pump Model Number 30100 30102 30104 30105 Pump Body (Includes 330-5311-000 (Phenolic) Bearing and Drive Shaft) Suction Housing 330-0945-000 EPDM...
  • Page 4 U.S.A. Thank you for choosing a Moyno Pump. Please take the time to complete this warranty registration form.Upon receipt of your form, your standard limited warranty on defective material and workmanship will be extended to twice the standard period of time at no additional cost to you. We appreciate your business and look forward to serving you in the future.
  • Page 5 © 1999 by Moyno, Inc. ® Moyno is a registered trademark of Moyno Inc. Printed in U.S.A.

This manual is also suitable for:

50030100301053010230104