Download Print this page

Association Groups; Compatibility Of Other Producers' Appliances In Z-Wave; Z-Wave Configuration Parameters; Alarms And Notifications - fakro ARZ Z-Wave User Manual

Electric roller shutter

Advertisement

possible via gate (Gateway Z-Wave),
remote control with a display, e.g.
ZRS24 remote control (FAKRO).

4. Association Groups.

There are three association groups in roller shutter ARZ Z-Wave:
1.
Life Line – group for position reporting roller shutter after each a stoppage and alarm reporting (overcurrent, damage
encoders). This group can be a maximum 1 device.
2.
Basic Repeat – group used to transfer the received basic commands to the devices included in this group. This group can be a
maximum 5 devices.
3.
Multilevel Repeat – group used to transfer the received multilevel commands to the devices included in this group. This
group can be a maximum 5 devices.

5. Compatibility of other producers' appliances in Z-Wave.

Z-Wave allows for the integration of other producers' appliances for lighting, heating, domestic automatic appliances, etc. The Z-
Wave works in the network as a "repeater", which enlarges the range of radio communication. The more appliances in the network,
the more resistant to disordered activities in the network.
Launch the "INCLUDE" procedure with a controller of the existing network, and then press the "Programming button" located on the
roller shutter which you want to link to the network.
Attention: All information concerning "Include" and "Associate" options in other producers' controllers can be found in their
user manuals.

6. Z-Wave configuration parameters.

No.
Value Default Value Size Description
12
1
1
2
13
1
1
2

7. Alarms and Notifications.

Notyfication type
Power Management
System
02.03.18 NC817-GB
2. Calibrate device from controller –
set parameter 12, value 1
3. Press UP button and hold it till
reach first end position.
4. Press STOP button to confirm first
end position.
5. Press DOWN button and hold it
till reach second end position.
6. Press STOP button to confirm
second end position.
1
Value 1 – calibrated
Value 2 – discalibrated – to enter the calibration mode must first time discalibrate and then
calibrate.
1
1 – FF go to Max
2 – FF go to previous position
Flashing...
Flashing...
Stop flashing and lit
cointinously within 2 sec.
Flashing...
Stop
cointinously within 2 sec.
Event
Over-load detected
System hardware failure (encoders damaged)
5/7
blinking
and
lit
©2018, FAKRO
-
-
-
-
-

Advertisement