Dear Customer, With the PODOLOG NOVA 3s, you have acquired a Footcare System that sets completely new standards in terms of functionality and performance. It has been developed throughout "based on best practice for use in the best pra-tices". You will clearly feel the many details that are taken into consideration in this new development, details that reflect over 90 years of experience and expertise.
Hazards caused by moving parts ................13 Potential risks for the user .....................14 3.4.1 Hazards caused by removed material ..............14 3.4.2 Allergy risks ......................... 3.4.3 Hazards caused by moving parts ................14 SET-UP .......................15 Technical safety ........................15 Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 5
Where can you get replacement dust filter bags? ..........35 Cleaning the motor unit ....................36 5.7.1 Loosening the sleeve ....................36 5.7.2 Easy cleaning of the motor unit ................36 Exchange of the alternate chuck ................Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 6
I can‘t switch the device on ..................50 11.2 The device is not responding ..................51 11.3 Resetting language and area of activity ..............51 POTENTIAL ERROR MESSAGES ON THE DISPLAY ......... 52 Operating instructions for PODOLOG NOVA 3s | REV. 0...
DEVICE DESCRIPTION FRONT VIEW Controller Display Dust filter bag drawer Handpiece Magnetic speed control knob Hose connection Operating instructions for PODOLOG NOVA 3s | REV. 0...
If the power cable is damaged, the device must be disconnected from the mains and may not be used any more. A damaged power cable may only be replaced by an authorised specialist. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Please take some time to read through these Operating Instructions carefully before setting up the PODOLOG NOVA 3s. This constitutes part of the medical product and should be kept in close proximity to the device itself. Please check that the delivery is complete.
Special country-specific requirements should also be taken into account. INTENDED USAGE The PODOLOG NOVA 3s Footcare System activates rotating tools which can be used to re- move hard skin, calluses or nails, for example. The device is intend-ed for use in the following fields of activity: Podiatry (medical footcare), cosmetic footcare, nail design, beauty, wellness and by doctors.
PODOLOG NOVA 3s. OPERATOR REQUIREMENTS The PODOLOG NOVA 3s Footcare System should only be used by podiatrists, pedicurists, cosmeticians, nail designers or doctors, who are aware of how the system operates and have received the necessary training.
The efficient suction technology of the PODOLOG NOVA 3s minimises the risk of inhaling dust which may potentially contain pathogens. The risk of infection can be further reduced by practising thorough antiseptic skin hygiene prior to the treatment.
Hair, jewellery and clothing may get caught in rotating parts. To avoid injury, long hair should be tied back or protected by a hairnet. In the interests of hy-giene, jewellery should not be worn. The user should wear clothes that cannot get caught in the tool. Operating instructions for PODOLOG NOVA 3s | REV. 0...
See Chapter 7.1 for tools which may be used. – The PODOLOG NOVA 3s is a STAND-ALONE device. To avoid elec- tro-magnetic interference, we do not envisage it being used in conjunc tion with other devices. Do not position the device directly next to or with other devices.
Page 16
Use of accessories, transducers and cables other than those speci- fied or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromag- netic immunity of this equipment and result in improper operation. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 17
Please ensure that you have easy access to the mains plug at all times so that the device can be unplugged from the mains without difficulty. The mains plug represents the separator to the mains pow- er supply. Operating instructions for PODOLOG NOVA 3s | REV. 0...
OPERATION Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 19
Filter bag change The icon appears as a reminder that a filter bag change is due. Service display The icon appears as a reminder that a service is due. Operating instructions for PODOLOG NOVA 3s | REV. 0...
= OFF (power switch off) = ON (power switch on) = Standby button on/off *If this is not the case, connect the filter bag to the sleeve. Please refer to page 32. Operating instructions for PODOLOG NOVA 3s | REV. 0...
The filter bag drawer must always be closed when the unit is in operation. The PODOLOG NOVA 3s switches off if the drawer is opened. Working with a full dust bag is not permitted. Note the dust filter change symbol on the display (see 5.5.2).
The PODOLOG NOVA 3s is now switched on and ready to use. The first time it is switched on, you must set the PODOLOG NOVA 3s to your language and your area of activity. Additionally, you can activate the service reminder function so that you are reminded in time when the next service is due.
Page 23
Menu display the first time the PODOLOG NOVA 3s is used: LANGUAGE SELECTION[M1] Deutsch [M3] Spanish [ M1 ] DEUTSCH [ M2 ] PYCCKNü [◄►] FRANCAIS [ M3 ] POLSKA [ + ] ENGLISH WELCOME! [ M1] CONTINUE [ M2] CANCEL...
Press lightly on the switch at the back end while the motors are running. The motor switches off and you can pause work and place the handpiece in the bracket provided. Operating instructions for PODOLOG NOVA 3s | REV. 0...
The power plug represents the sep- arator to the mains power supply. If the PODOLOG NOVA 3s is not used for an hour, it automatically switches to ECO mode. It can be easily switched on again by pressing the standby button SETTINGS 5.2.1...
[ M2 ] 15.000 RPM [ M3 ] 20.000 RPM You will find the maximum permitted rotational speeds for all nail file drills and grind- ers in the “Rotary Instruments” chapter of the HELLMUT RUCK GMBH Catalogue. 5.2.3 RIGHTHAND / LEFTHAND DIRECTION OF ROTATION You can set your tool to righthand or lefthand rotation depending on which tool you are using and on whether you are right-handed or left-handed.
[ + ] button increases the extraction power level. Pressing and holding the corres- ponding button controls the extraction power level in the desired direction. There are five extraction power levels. Operating instructions for PODOLOG NOVA 3s | REV. 0...
With a short press on [M1], [M2] or [M3], the corresponding stored value is called. You can change the settings at any time while the machine is in oper-ation. The speed setting may not exceed the permitted maximum speed of your tool. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Tools should only be changed when the handpiece motor has been switched off. The tool shaft must be fully inserted! ERGONOMIC HANDPIECE GRIP 5.4.1 FOUNTAIN PEN GRIP Fine work can be done ergonomically and accurately using the fountain pen grip. Operating instructions for PODOLOG NOVA 3s | REV. 0...
The Info menu offers you the option of calling up the following information and functions. Scroll through the individual menu items with the [ + ] and [ - ] buttons.. Operating instructions for PODOLOG NOVA 3s | REV. 0...
3s. This is either after 900 operating hours or at the latest, 24 months after you purchased the device. INFO MENU NEXT RECOMMENDED SERVICE: 01/2014 OR AFTER 499 OPERATING HOURS [+/-] SCROLL [i] MAIN MEN Operating instructions for PODOLOG NOVA 3s | REV. 0...
5.5.3 ACTIVATING THE SERVICE REMINDER If you activate the Service reminder function, your PODOLOG NOVA 3s will let you know when the next service is due. You can activate/deactivate this func-tion through the INFO MENU. After 900 operating hours the maintenance symbol appears on the display.
[ i ] button to access the INFO MENU. There, you can scroll with the [ + ] or [ - ] buttons to the Filter change menu item: Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 34
HAS A NEW FILTER BEEN INSTALLED?BEEN INSTALLED? HAUPTMENÜ 02 I 0 [M1] YES [M2] CANCEL Confirm that the change has been made by pressing the [M1] button, which then returns you to the STANDARD MENU. Operating instructions for PODOLOG NOVA 3s | REV. 0...
5.6.2 WHERE CAN YOU GET REPLACEMENT DUST FILTER BAGS? New dust filter bags can be ordered from HELLMUT RUCK GmbH under the item number 11001. Please ensure that you only use original dust filter bags from the manufacturer.
EASY CLEANING OF THE MOTOR UNIT Do not use disinfecting sprays. Dampness could penetrate and lead to bearing damage. Use RUCK alcohol-free disinfectant cloths (item no 2942801) for gentle cleaning and disinfection. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Also check the housing and in particular the glass front for damage. To disinfect all parts of the controller and handpiece, use RUCK alcohol-free disinfection wipes (art. no. 2942801). These can be found in our main cata-logue or at www.hellmut-ruck.de.
You can use all rotary instruments (cutters, grinders, polishers) with a stand-ardised shaft diameter of 2.35 mm, which have a CE label identifying them as a medical product. You will find a wide range in our catalogue or at: www.hellmut-ruck.de. More information can be found in the standard DIN EN ISO 1797-1.
Page 39
Item no.: 48237 Freestanding handpiece holder Item no.: 4823401 Handpiece holder for PODOLOG CLASSIC furniture Item no.: 4823801 Handpiece holder for wall or cabinetk Item no.: 11067 Interchangeable chuck for PODOLOG NOVA 3s Operating instructions for PODOLOG NOVA 3s | REV. 0...
280 l / min (- 10 %) Length of power cable in cm Length of hose in cm We are not aware of any electromagnetic interactions between the PODOLOG NOVA 3s and any other equipment. Operating instructions for PODOLOG NOVA 3s | REV. 0...
70 °C (at relative air humidity from 15 % up to 93 %, non-condensing) Air pressure 700 hPa (≈ 3000 metres above sea level) - 1060 hPa Operating instructions for PODOLOG NOVA 3s | REV. 0...
Guidelines and manufacturer’s declaration – electromagnetic interference The PODOLOG NOVA 3s is designed for use in electromagnetic environments as specified below. The customer or client using PODOLOG NOVA 3s hould ensure that the device is used in the prescribed environment.
Page 43
Guidelines and manufacturer’s declaration – electromagnetic interference immunity The PODOLOG NOVA 3s is designed for use in electromagnetic environments as specified below. The customer or user of the PODOLOG NOVA 3s should ensure that the device is used in the prescribed environment.
Page 44
IEC 61000-4-4 ment standards. Surge voltages L-PE and N-PE: 2kV The quality of the according to IEC L-N: 1kV supply current 61000-4-5 shall correspond to typical commercial or hospital environ- ment standards. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 45
0° at 0° plying the PODOLOG NOVA 3s with current from an uninter- ruptible power system or via battery. NOTE: UT is the supply voltage before implementation of the test level Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 46
Guidelines and manufacturer’s declaration – electromagnetic interference immunity The PODOLOG NOVA 3s is designed for use in electromagnetic environments as specified below. The customer or user of the PODOLOG NOVA 3s should ensure that the device is used in the prescribed environment.
Page 47
Above a frequency range of 150 kHz to 80 MHz the magnetic field strength should be less than 3V/m. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 48
Recommended safety distances between portable and mobile equipment HF telecommunication equipment and the PODOLOG NOVA 3s. The PODOLOG NOVA 3s is designed for use in electromagnetic environments as specified below. The customer or user of the PODOLOG NOVA 3 can contribute to avoiding electro-...
Within the scope of the warranty, HELLMUT RUCK GmbH will, at no charge, either repair or replace the defective products – at RUCK’s discretion. The prerequi-site is carriage-paid shipment of the defective product together with the purchase receipt.
The operating hours counter / the time remaining until the next service as shown in the Info menu are not changed during the reset. Operating instructions for PODOLOG NOVA 3s | REV. 0...
LIMIT TEMPERATURE, REDUCE LOAD! INFO AFTER-COOLING ACTIVE! INFO OVERHEATING, AFTER-COOLING ACTIVE! INFO OVERHEATING, SWITCHING OFF INFO CAUTION OVERHEATING, CHANGE FILTER BAG! INFO CAUTION OVERHEATING, CHANGE FILTER BAG! COOLING-DOWN PHASE 15 MIN! Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 52
Videotip In an application video, we show you how the cutter for-ceps work. You will find the video on our online shop with the product. Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 53
NOTES You will find the safety, operating and hygiene recommendations from Busch on our website at: www.hellmut-ruck.de/downloadbereich/SuH_D.pdf Or simply scan the QR code: Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 54
Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 55
Operating instructions for PODOLOG NOVA 3s | REV. 0...
Page 56
HELLMUT RUCK GmbH Daimlerstraße 23 D -75305 Neuenbürg fon +49 (0)7082. 944 20 fax +49 (0)7082. 944 22 22 e -Mail kontakt @ hellmut-ruck.de web www.hellmut-ruck.de Operating instructions for PODOLOG NOVA 3s | REV. 0...
Need help?
Do you have a question about the PODOLOG NOVA 3s and is the answer not in the manual?