jbc FAE2-5A Instruction Manual

Fume extractor
Hide thumbs Also See for FAE2-5A:

Advertisement

Quick Links

www.jbctools.com
INSTRUCTION MANUAL
Fume Extractor
Ref. FAE2-5A

Advertisement

Table of Contents
loading

Summary of Contents for jbc FAE2-5A

  • Page 1 INSTRUCTION MANUAL Fume Extractor Ref. FAE2-5A...
  • Page 2: Packing List

    Packing List The following items should be included: Fume Extractor ......... 1 unit RJ12 direct cable ........2 units Ref. FAE2-5A Ref. 0019751 Cleaning stick ..........1 unit Ref. 0004009 Compact Filter + Pre-filter ....1 unit Ref. FAE2-100 *Already assembled Manual ............
  • Page 3 w w w.jbctools.com Features Aspiration tube for up to 4 stands (2 work Aspiration tube for up to 4 stands (2 work intakes configuration) or for 1 workbench intakes configuration) or for 1 workbench (4 work intakes configuration). (4 work intakes configuration). Aspiration tubes for workbenchs...
  • Page 4 Features Pre-filter Ref. FAE2-110 Compact filter + Pre-filter Ref. FAE2-100 Important: Before using, unseal the filter and remove the bottom protection of the compact filter.
  • Page 5 For modular stands Connect the Fume (From SD versions Extractor to the flexible onwards) arm or to the accessory for stand aspiration Ref. FAE060 For compact stations (From B versions onwards) Fume Extractor Ref. FAE2-5A Visit www.jbctools.com for further details.
  • Page 6 Ref. FAE020 To be assembled directly on your workbench (hole drilling required) Flexible Hoses Ø50 Ref. FAE010 Lenght: 1,5 m (59.05 in) Connect the Fume Extractor to the flexible arm Fume Extractor Ref. FAE2-5A Visit www.jbctools.com for further details.
  • Page 7: Communication Ports

    w w w.jbctools.com Communication ports RJ12 connections take precedence over USB connections. The fume extractor will only attend RJ12 port. Connection with Excellence range Connect up to 2 stations directly to the fume extractor using RJ12 ports. For a correct operation always update the soldering stations with the latest software version available. The minimum required version is number 8886160 for DDE, HDE &...
  • Page 8 Aspiration ports control The pedal connection takes precendence over the RJ12 connection, the equipment will only attend the Pedal port. For 2 work intakes configuration: For 2 work intakes configuration: If only 1 station is connected to Port1, the If 1 station is connected to Port2, the station station will detect the 2 work intakes identified will only detect the work2 intake identified as as FAE_a (work1) and FAE_b (work2).
  • Page 9 LAN as the QSC (connected by Wifi or Ethernet) by tipping the address in a Web Browser (see page 17). JBC stations featuring USB connectors are supported except for JT-D, TE-D and older hot air stations. PHB/PHS preheaters and older are not supported.
  • Page 10: Working Modes

    Autonomous Pedal Activate the vacuum system with the pedal without being connected to a JBC station. For 2 work intakes configuration, each pedal control its associated port, whereas for 4 intakes configuration, pedal port1 controls work1 and work2 intakes and pedal port2 controls work3 and work4 intakes.
  • Page 11: Control Process

    w w w.jbctools.com Control Process Main Screen for 2 intakes configuration Aspiration program F i l t e r F l o w F i l t e r F l o w High, medium and low Saturation 20% Saturation 20% 100% Carbon life 90% Carbon life 90%...
  • Page 12 Control Process Main Menu Original Pin: 0105 M a i n m e n u Exit 1 Reset 2 Unit 3 Port 4 Filter set 5 Counters 6 Program version For 2 work intakes configuration U n i t P o r t F i l t e r s e t 1 Continuous mode 1 Program Ctm - 100%...
  • Page 13 w w w.jbctools.com Control Process Unit Screen U n i t It opens all aspiration intakes with the selected program 1 Continuous mode (high, medium, low or custom). 2 Beep 3 PIN 4 Change PIN When option 4 is selected, 5 Work intakes the 4 intakes wil work as workbench extraction...
  • Page 14 Control Process Port Screen for 2 intakes configuration P o r t Selects between a Preset (High, 1 Program Ctm - 100% Medium, Low) and Custom 2 Delay port 1 aspiration program. 3 Delay port 2 4 Pedal port 1 5 Pedal port 2 B a c k D e l a y t o s t o p p o r t 1...
  • Page 15 w w w.jbctools.com Control Process Port Screen for 4 intakes configuration P o r t 1 Delay port 1 2 Delay port 2 3 Delay port 3 4 Delay port 4 5 Pedal ports 1 and 2 6 Pedal ports 3 and 4 B a c k D e l a y t o s t o p p o r t 1 P e d a l p o r t 1 a n d 2...
  • Page 16 Fume extractor configurations Some parameters, features and the performance vary depending on fume extractor configuration, see the following table: 2 work intakes 4 work intakes Work aspiration intakes Stand aspiration intakes Not available Flow per work intake 76 m3 / h (44.73 cfm) 52 m3 / h (30.6 cfm) Flow per stand intake 4 m3 / h (2.35 cfm)
  • Page 17 Stations Update the equipment software Fume extractor can be updated by means of JBC Updater software. If you want to update the equipment be aware there is no station connected to RJ12 connectors. If a station is connected by means RJ12 port the update process will not start.
  • Page 18: Maintenance - Filter Replacement

    Maintenance - Filter replacement - The unit notifies through both the display and the LED when filters need maintenance. - To replace the filters, first turn the fume extractor off. Then remove the cover by opening the quick release lever of the casing. - If once the pre-filter has been changed the saturation indicator is on, it means that the Pre-filter...
  • Page 19 w w w.jbctools.com Maintenance - Valves - Check the status of the valves when replacing the pre-filter or the compact filter. - Use the cleaning stick if necessary and clean with alcohol to remove dirt residues. Clean the disc and the gasket on both sides Intake valve Ref.
  • Page 20 Safety Follow safety guidelines to prevent electric shock, injury, fire or explosion. - The equipment is only designed to filtrate the fumes generated by soldering. - Do not use the units for the filtration of combustible, explosive or corrosive gasses. Incorrect use may cause fire.
  • Page 21: Exploded View

    w w w.jbctools.com Exploded View...
  • Page 22 Notes...
  • Page 23 w w w.jbctools.com...
  • Page 24: Specifications

    Specifications FAE2-5A 120V 50/60Hz. Input power: 500W FAE2-5A 230V 50/60Hz. Input power: 500W FAE2-5A 100V 50/60Hz. Input power: 320W - Weight: 33,6 kg (74.08 lb) - Dimensions: 558 x 292 x 562 mm (21.97 x 11.50 x 22.13 in) - Fuse:...

Table of Contents