Starting up and Shutting down the System
Starting up and shutting down
C-arm Operation
Conducting Examinations 1
Starting an Examination
Selecting the APR
Conducting Examinations 2
Fluoroscopy
Adjusting Image
Useful Functions
Smart C Memory
Frame Memory
Changing Fluoroscopy Conditions
Digital Radiography
Loop Memory
Apply power only to the C-arm
M516-E044A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPESCOPE ACTENO and is the answer not in the manual?

Questions and answers

Summary of Contents for Shimadzu OPESCOPE ACTENO

  • Page 1 M516-E044A Contents of all manuals give priority to Instruction Manual of OPESCOPE ACTENO. OPERATION GUIDE Starting up and Shutting down the System Starting up and shutting down C-arm Operation Conducting Examinations 1 Starting an Examination Selecting the APR Conducting Examinations 2...
  • Page 2 C-arm cart function correctly? Is the C-arm cart’s brake applied? Operate the brake. Do the brakes of the monitor cart function Notify correctly? Notify Meaning of : If you discover an abnormality, notify your Shimadzu service agent. tel: Responsible person: M516-E044...
  • Page 3: Starting Up And Shutting Down The System

    Starting up and Shutting down the System Instruction Manual 3.3 Connecting and Dismantling the System, 3.4 Turn the Power ON/OFF Starting up System switch Back of the monitor cart Front of the monitor cart C-arm Connect the C-arm Connect the C-arm Insert the power Turn the power Wait for the system...
  • Page 4 Starting up and Shutting down the System Instruction Manual 3.6 Positioning C-arm Operation Lamp on (C-arm unlocked) Lamp off (C-arm locked) I.I. handle I.I. handle (option) (option) Handle Handle Handle Handle I.I. handle Handle (option) Press each lock switch. Move the C-arm while holding the When you have set the position, handles.
  • Page 5: Starting An Examination

    Conducting Examinations 1 Instruction Manual 3.7 Starting the Study Starting an Examination It takes a short while for the system to start-up. If the preparation of fluoroscopy image functions is completed before starting an examination, you can perform emergency fluoroscopy. For a Registered Study This selection is only possible on the reference monitor.
  • Page 6 Conducting Examinations 1 Instruction Manual 2.2.2 LCD Display, 3.8 Selecting the APR Selecting the APR (Immediate) Startup Screen APR Selection Screen (Immediate) Turn (Releasing the restriction on X-ray Select the APR. exposure) ON (lit). The basic screen is displayed and the The APR selection screen (Immediate) is parameters registered in the APR are loaded.
  • Page 7: Adjusting Image

    Conducting Examinations 2 Instruction Manual 3.9 Fluoroscopy Fluoroscopy Memo If the fluoroscopy timer beep sounds If the fluoroscopy timer preset time is exceeded, the beep sounds. The alarm can be stopped by pressing fluoroscopy timer beep sound reset switch. Press X-ray exposure Irradiation indicator (fluoroscopy) switch or depress the left foot...
  • Page 8 Conducting Examinations 2 Instruction Manual 3.9 Fluoroscopy, 3.10 Changing I.I. Field Size (Zooming-up Images), 3.11.4 Setting the Beam Hardening Filter Changing Fluoroscopy Conditions Switches the Changing the tube voltage. Changing the filter. X-ray adjustment Increases the tube mode. The filter is changed each time voltage pressed.
  • Page 9 Conducting Examinations 2 Instruction Manual 3.12 Digital Radiography Digital Radiography Memo The digital radiography conditions are set automatically based on the fluoroscopy conditions. For this reason, before taking a radiograph you should turn the IBS function ON and perform fluoroscopy until the fluoroscopy image is stabilized.
  • Page 10: Useful Functions

    Useful Functions Instruction Manual 3.14 Useful Functions, 4.2.1 Saving Images Smart C Memory Store the following conditions in two Smart C Memory. • Fluoroscopy conditions • Settings of the collimators • Beam hardening filter • Image rotation and inversion • I.I. field size Smart C memory Storing Calling Up...