Frico Thermoplus EC Series Original Instructions Manual

Frico Thermoplus EC Series Original Instructions Manual

Advertisement

SE
.... 7
ES
.... 47
NL
.... 87
GB
.... 17
DE
.... 57
PL
.... 97
Original instructions
Thermoplus
NO
.... 27
FI
.... 67
RU
.... 107
FR
.... 37
IT
.... 77

Advertisement

Table of Contents
loading

Summary of Contents for Frico Thermoplus EC Series

  • Page 1 Original instructions Thermoplus ..7 ..17 ..27 ..37 ..47 ..57 ..67 ..77 ..87 ..97 ..107...
  • Page 2: Mounting On The Wall

    Thermoplus Thermoplus EC Thermoplus ECV/ECVTN ø22 (2x) Type Type [mm] [mm] [mm] [mm] EC450 1076 ECV/ECVTN300 EC600 1505 ECV/ECVTN550 1505 1810 1200 1810 1200 EC750 ECV/ECVTN700 EC900 2140 1800 Mounting on the wall Mounting on the ceiling Ceiling fixture TF1...
  • Page 3 Thermoplus Minimum mounting distance [mm] 1800 Flammable material Flammable material, e.g curtain...
  • Page 4 Thermoplus...
  • Page 5: Technical Specifications

    Thermoplus Technical specifications Thermoplus EC (IP20) Type Output (1) Voltage (2) Amperage (3) Max. surface Weight (6) temp. (4) [°C] [kg] EC45021 230V~ EC60021 230V~ EC75021 230V~ EC90021 230V~ EC90031 400V2~ Thermoplus ECV (IP44) Type Output (1) Voltage (2) Amperage (3) Max.
  • Page 6: Wiring Diagram

    Thermoplus Wiring diagram Control by thermostat °C °C TAP16R TAP16R 230V~ 230V~ °C A1A2 EC/ECV 230V~ °C EC/ECV 400V2~ Control by built-in thermostat 230 V (ECV) TAP16R ECVTN...
  • Page 7 Thermoplus 3. Break off the top spacing part of the Installation and operating instructions brackets at the break mark. General Instructions 4. Fasten the back plate to the brackets. Read these instructions carefully before 5. In the connection box on the heater there installation and use.
  • Page 8 Thermoplus Residual current circuit breaker Safety When the installation is protected by means • For all installations of electrically heated of a residual current circuit breaker, which products should a residual current circuit trips when the appliance is connected, breaker 300 mA for fire protection be used. this may be due to moisture in the heating •...
  • Page 9: Symbols On The Display

    Thermoplus Control ECVTN Thermoplus ECVTN has a digital display on which all settings are made. Symbols on the display 1. Day of the week 2. Time and date 3. Selected menu/Current temp (actual value) °C 4. Set temp (set point) °C 5.
  • Page 10 Thermoplus Start up Using the menu This is what the display looks like at first start. Start the Navigate menu through the Exit the menu* options Time Temp Control (F) Arrow buttons Select button *Or wait 30 secs and exit automatically. Turning off and on Locking the keypad To standby*...
  • Page 11 Thermoplus Basic settings Time and date To be able to use all the functions you need to set the time and date first. Navigate to the correct time* *Repeat the last two steps to set minutes, day, month and year. The correct day of the week is set automatically.
  • Page 12 Thermoplus Other settings Time and date Light and contrast Set time format Set the light intensity of the LED Press Press and navigate to SET. and navigate to SET. Select with Select with Navigate to DISP and Navigate to LED and select with select with Navigate between 12- and 24-hour format.
  • Page 13 Thermoplus Adaptive function operation time as a percentage for the last The thermostat has a function which works 7/30/365 days. out when the heating should start to give the correct temperature at the correct time. It is activated on delivery, but can be turned off: The LED allows you to see the current status of the thermostat.
  • Page 14 Thermoplus Energy saving programs Save energy cleverly and easily! With these programs the heating is adapted to your actual needs and the heat is turned down when it isn’t needed. There are four program options: Preset Preset Program your own Frost protection for office for home...
  • Page 15 Thermoplus Frost protection program Press and navigate to SET. This program is ideal for when you want to protect against frost damage in premises Select with which are standing empty or unused for long periods, such as holiday homes and Navigate to FP, warehouses, or when you will be away from select with...
  • Page 16 Thermoplus Sitemap of the menu This is how the menu in the thermostat is structured. Here you can quickly see where all the functions and settings are. CONT PROG UTIL Set the display’s contrast Start/stop program Show connected time in % 24 HR Home program Office program...
  • Page 20 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...

Table of Contents