Clean Water Systems 5900-BT Neutralizer Operation & Maintenance Manual page 13

Table of Contents

Advertisement

5900S Neutralizer Operation & Maintenance Manual
Master Programming Mode
To enter Master Programming Mode press and hold both buttons for 5 seconds. To change a
value, Press the Set/Change buttons. When done, press the Menu/Enter button to go to the
next step.
1. Regeneration Time (r)
The first master programming display viewed is the option setting for Regeneration Time. It is
identified by the letter 'r' in the left digit. Set the desired time of day that a regeneration (the
backwash and rinse cycles) will occur, when required.
We recommend setting the system to backwash at 2 AM, or at any time that it is unlikely that
any water will be used.
If you have 2 or more filters, make sure they are programmed to start an hour apart, so they do
not backwash at the same time.
The first digit(s) indicates the Hour and the other digit indicates A.M. or P.M.
Example: 12 A.M. regeneration time ‐ [ r 12A] (factory setting)
2. Regeneration Cycle Step Programming Times
The next 3 displays viewed are part of a series of option settings used to program the
Regeneration Cycle which is where the filter backwashes and rinses itself. Up to 3 steps can be
programmed and they are: Backwash, Rest, and Rapid Rinse.
Each display is used to set the duration time in minutes for that specific step in a regeneration
cycle. Regeneration steps are skipped by setting the display to 0 as shown below:
Set each step according to the values below, appropriate for a 5900‐BT filter system:
1
10 minutes. This is the BACKWASH cycle. [ 1 - 10] (Set for 6 minutes minimum)
5 minutes. This is the REST cycle. [ 2 - 5]
2
6 minutes. This is the RAPID RINSE cycle. [ 3 - 05] (Set for 4 minutes minimum)
3
4
Next step will be "bE 1". If you are using the Bluetooth Legacy App, the 01 means that it's ready.
5
Next and final step is bbPP is displayed for one second, then password is displayed.
Press the menu/enter button, and now you are back to the home service screen (displaying the
clock time and the number of days until backwash). bE is for Bluetooth enabled.