Mechanical Mounting - Datalogic SG-PSB Series Instruction Manual

Safety light curtain protective armor stand
Table of Contents

Advertisement

If a body protection is being used, compliance with the EN 999 standard
'Safety of machinery - Positioning of safeguards with respect to the
approach speeds of parts of the human body' is required.
NOTES

MECHANICAL MOUNTING

The SG-PSB guard can house a number of different products. For this reason, 5 different
bracket kits are available:
ST-PS4-SG/SE (95ASE1750): for the installation of light curtains of the SG/SE/SG Body
Compact series, finger/hand protection, protected height 150÷1050mm and body
protection, protected height 500, 800, 900mm;
ST-PS6-SG/SE (95ASE1760): for the installation of light curtains of the SG/SE/SG Body
Compact series, finger/hand protection, protected height 1200÷1800mm and body
protected height 1200mm;
ST-PS4-SG Body (95ASE1730): for the installation of light curtains of the SG Body Big
series, body protection, protected height 500, 800, 900mm;
ST-PS6-SG Body (95ASE1740): for the installation of light curtains of the SG Body Big
series, body protection, protected height 1200mm;
ST-PS-DM (95ASE1770): for the installation of deviating mirrors SG-DM.
An extra plate may be installed on the accessory, to compensate for the effects of collisions,
vibrations and uneven floor surfaces:
SG-P (95ASE2290): for the installation of a double plate with compensation springs.
The instructions for the installation of these accessory kits can be found below:
SG2, SG4-B, SE, SG BODY COMPACT SERIES MOUNTING
With the help of the ST-PS4-SG/SE kit, for product versions from 150 to 1050 mm or of the
ST-PS6-SG/SE kit, for product versions from 1200 to 1800 mm, build sub-assemblies as
shown in Fig. 2 then insert and fasten them to the grooves on the guard. Do not tighten
completely the M5 nut under the bracket (in the following example a SG2/4 base profile is
used).
M5 nut
SG-PSB INSTRUCTION MANUAL
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sg-psb 600Sg-psb 1000Sg-psb 1200Sg-psb 1900Sg-psb 1650

Table of Contents