  • Page 2: General Information

    SG-PSB INSTRUCTION MANUAL GENERAL INFORMATION The SG – PSB accessory is a guard, which comprises a drawn aluminium column and a steel base. The base is made of two plates. Their inclination can be adjusted by means of three dowels and their angular position can be adjusted through 3 rough adjustment slots and 3 fine adjustments slots.
  • Page 3: Mechanical Mounting

    SG-PSB INSTRUCTION MANUAL If a body protection is being used, compliance with the EN 999 standard 'Safety of machinery - Positioning of safeguards with respect to the approach speeds of parts of the human body' is required. NOTES MECHANICAL MOUNTING The SG-PSB guard can house a number of different products.
  • Page 4 SG-PSB INSTRUCTION MANUAL Tighten partially, (leave some clearance) Fig. 2 Once the assembly is completed, remove the column cover by unscrewing the two M8x20 ISO 7380 screws (Fig. 3) and insert the assembly in the internal guides. Fig. 3...
  • Page 5 SG-PSB INSTRUCTION MANUAL M5x8 5931 Once the product has been completely inserted and its position along the column adjusted, replace the cover (Fig. 4). To adjust the position of the product along the column, slightly unscrew the M5x8 UNI 5931 screws, which can be accessed from the outside by using a special Allen key;...
  • Page 6 SG-PSB INSTRUCTION MANUAL SG-DM DEVIATING MIRRORS MOUNTING Using the ST-PS-DM kit, mount the carter for the deviating mirror in use. Make sure that the M8 T-nut is aligned with the corresponding central groove of the protective stand and that the side edges of the mirror's carter are aligned with the corresponding longitudinal guides in the protective stand (Fig.
  • Page 7 SG-PSB INSTRUCTION MANUAL ADJUSTMENT ADJUSTING THE VERTICAL AXIS AND THE ANGULAR POSITION OF THE PLATES Fasten the plate to the floor in the desired rough angular position, according to the positions established by the reference grooves (main angles: 0° - 45° - 90° for each quadrant); to do this, use the 3 slots on the bottom plate and M10 screws.
  • Page 8: Installation

    SG-PSB INSTRUCTION MANUAL INSTALLATION LIGHT CURTAIN INSTALLATION For light curtain alignment procedure, see the instruction manual of each specific model. INSTALLATION OF SG-PSB WITH SG-DM SG-PSB with Emitter SG-PSB with Receiver SG-PSB with SG-DM SG-PSB with SG-DM Fig. 9 1. Define the area to protect and the precise positions where the deviating mirrors and the emitting and receiving units of the light curtain will be installed.
  • Page 9: Available Models

    SG-PSB INSTRUCTION MANUAL The laser pointer, due to mechanical tolerance issues related to its use in combination with the bar, provides an approximate measurement. It might be necessary to carry out small adjustments to the alignment of the two units following the regular ALIGNMENT PROCEDURE described in the safety light curtains Instruction Manual.
  • Page 10: Overall Dimensions

    WARRANTY DATALOGIC AUTOMATION warrants its products to be free from defects. DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products.