Technical specifications
SITRANS P pressure transmitter, Z series for gage pressure
Mode of operation
Measuring principle
Input
Measured variable
Measured range
Output
Current output signal
Measuring accuracy
Error in measurement (at 25 °C
(77 °F), including conformity error,
hysteresis and repeatability)
Response time T
99
Long-term drift
• Start of scale
• Measured span
Influence of ambient temperature
• Start of scale
• Measured span
Rated conditions
Medium conditions
• Process temperature
Degree of protection to EN 60529
Ambient conditions
• Ambient temperature
• Storage temperature
Selection and Ordering data
SITRANS P pressure transmitters, Z series for pressure
2-wire system, characteristic rising
Measured range
0 ... 16 bar g
(0 ... 232 psi g)
0 ... 25 bar g
(0 ... 363 psi g)
Other version for measuring range
Measuring range: ... to ... bar g (psi g)
D) Subject to export regulations AL: N, ECCN: EAR99H.
© Siemens AG 2008
SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure
Thin-film strain gage
Realtive pressure
0 to 16 bar g (0 to 232 psi g) or
0 to 25 bar g (0 to 363 psi g)
4 ... 20 mA
To EN 60770-1
0.5% of full-scale value-typical
< 0.1 s
0.3% of full-scale value/year - typ-
ical
0.3% of full-scale value/year - typ-
ical
0.3%/10 K (0.3%/10 K) of full-
scale value - typical
0.3%/10 K (0.3%/10 K) of full-
scale value - typical
-30 ... +120 °C (-22 ... +248 °F)
IP65
-25 ... 85 °C (-13 ... +185 °F)
-50 ... 100 °C (-58 ... +212 °F)
Max. working pressure
32 bar g
(464 psi g)
64 bar g
(928 psi g)
1 bar g ( 14.5 psi g), add Order code and plain text:
Design
Weight
Wetted parts materials
• Measuring cell
• Process connection
• Gasket
Process connection
Power supply
Terminal voltage on pressure trans-
mitter
• For current output
Certificate and approvals
Classification according to pressure
equipment directive
(DRGL 97/23/EC)
Dimensional drawings
SITRANS P pressure transmitters, Z series (7MF1562-...), dimensions in
mm (inch)
Schematics
SITRANS P pressure transmitters, Z series (7MF1562-...), connection dia-
gram
Z series for gage pressure
0.2 kg ( 0.44 lb)
Al
O
- 96%
2
3
Brass, mat. No. 2.0402
Viton
Male thread G½B
1
female thread G
/
B
8
10 to 36 V DC
For gases of fluid group 1 and
liquids of fluid 1; complies with
requirements of article 3, para-
graph 3 (sound engineering prac-
tice)
Order No.
Order code
7 M F 1 5 6 2 -
7 7 7
0 0
D)
3 C B
3 C D
9 A A
Siemens FI 01 · 2009
2
7 7 7
H 1 Y
2/5

Advertisement