Siemens SITRANS P Brochure & Specs page 18

Measuring instruments for pressure
Table of Contents

Advertisement

SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure
ZD series for gage and absolute pressure
• Upper and lower current saturation limit
• Electrical damping
The other two keys are used to set the values in the individual op-
erating modes.
2
Two LED indicators are fitted above the display to monitor the set
range and the status.
The green LED signals that the measured pressure lies within the
set limits. The red LED lights up when the measured pressure
lies outside the set limits and when there is an error.
Technical specifications
SITRANS P pressure transmitters, ZD series
Mode of operation
Measuring principle
Input
Measured variable
Measured range
0 ... 2 bar (0 ... 29 psi)
0 ... 10 bar (0 ... 145 psi)
0 ... 50 bar (0 ... 725 psi)
0 ... 200 bar (0 ... 2900 psi)
0 ... 400 bar (0 ... 5800 psi)
Measured range
0 ... 2 bar (0 ... 29 psi)
0 ... 10 bar (0 ... 145 psi)
0 ... 50 bar (0 ... 725 psi)
0 ... 200 bar (0 ... 2900 psi)
0 ... 400 bar (0 ... 5800 psi)
Range adjustment (turndown)
Output
Output signal
Lower current limit
Upper current limit
Output protected against
Max. load
Voltage measurement
Measuring accuracy
Error in measurement (including
non-linearity, hysteresis and repeat-
ability, at 25 °C (77 °F))
Adjustment time
Long-term drift
Influence of ambient temperature
Vibration influence
Power supply effect
2/18
Siemens FI 01 · 2009
© Siemens AG 2008
Thin-film strain gage
Gage and absolute pressure
Resolution
0.6 mbar (0.008 psi)
3 mbar (0.044 psi)
15 mbar (0.218 psi)
60 mbar (0.9 psi)
120 mbar (1.8 psi)
Overload limit
5 bar (72.5 psi)
25 bar (363 psi)
120 bar (1740 psi)
500 bar (7250 psi)
600 bar (8700 psi)
5:1
4 ... 20 mA
min. 3.6 mA
max. 23 mA
Reversed polarity, overvoltage
and short-circuiting
R
= (U
- 12 V) / 0.023 A
B
H
Linear rising
To EN 60770-1
< 0.25% of full-scale value (typi-
cal), max. 0.5%
< 100 ms
0.25% of full scale value/year
< ±0.25%/10 K (< ±0.25%/10 K)
of full-scale value
0.05%/g to 500 Hz in all directions
(to IEC 68-2-64)
< ±0.01%/V of full-scale value
Rated conditions
Ambient conditions
• Ambient temperature
• Storage temperature
Medium conditions
• Process temperature
Degree of protection
Electromagnetic compatibility
• Emitted interference and interfer-
ence immunity
Displays and controls
Display
Decimal point
Limit values
Limit violation display
Parameterization
Units
Damping
Design
Weight
Electrical connection
Process connection
Version of housing/process connec-
tion
Material
Non-wetted parts materials
• Field housing
• Cover
Wetted parts materials
• Measuring cell
• Gasket
• Process connection
Power supply
Terminal voltage on pressure trans-
mitter (U
)
H
Certificate and approvals
Classification according to pressure
equipment directive 97/23/EC
-25 ... +85 °C (-13 ... +185 °F)
-40 ... +85 °C (-40 ... +185 °F)
-30 ... +100 °C (-22 ... +212 °F)
IP65 to EN 60529
To EN 61326/A1 appendix A
(1998)
LCD, max. 5 digits, digit height
9 mm
Freely parameterizable
Freely parameterizable
Red LED and message on LCD
(↑ symbol /↓ symbol in case of
limit violation in upward / down-
ward direction)
With 3 keys
mA or % or physical variable
(default setting: bar)
Other dimensions: mbar, kPa,
MPa, mmH
0, mH
0, psi, inH
0,
2
2
2
mmHg, kg/cm², torr, atm
Between 0.1 and 100 s
(increment: 0.1 s) freely parame-
terizable
≈0.6 kg (≈1.32 lb)
Using 2-pole plug connector with
M16x1.5-Cable inlet to
EN 175301-803A, plastic
• Male thread G½B and female
1
thread G
/
B
8
• G½B to EN 837-1
• Female thread: ½-14 NPT
• Radial (type A), can be swiveled
by max. ±120° (α)
• Axial (type B), can be swiveled
by max. ±360°
Ø 80 mm (3.15 inch), stainless
steel mat. No. 1.4016
Stainless steel, mat. No. 1.4016
with glass
Al
O
2
3
Viton
Stainless steel, mat. No.
1.4571/316Ti
12 ... 30 V DC
For gases of fluid group 1 and liq-
uids of fluid 1; complies with
requirements of article 3, para-
graph 3 (sound engineering prac-
tice)