Hardware Problems (Pc, Modem, Isdn Ta.) - Gigaset M101 Data Operating Instruction

The cordless v.24/rs232 interface for pcs, modems and other equipment
Table of Contents

Advertisement

16.4.99
Tips & tricks, settings
Fault
The modem parameter request
function is not working or is not
correct.
For example, under Win 95 with
<Start><Settings><Control
Panel><Modem Proper-
ties><Diagnostics><Details>
Data transmission with
Xmodem is very slow.
Laplink 7 .0 is not working.

Hardware problems (PC, modem, ISDN TA.):

Fault
PABX (telecommunications
system) cannot be configured
via a Gigaset M101 Data.
ELSA TagGo2000 / ISDN con-
figuration not possible.
The ELSA TanGo 2000 terminal
adapter cannot be used under
AOL.
Timers such as "Heliowatt" can-
not be programmed.
The ACER ISDN T30 terminal
adapter cannot be operated un-
der AOL with the initialisation
string specified in the manual.
The Hagenuk Speed Dragon
terminal adapter cannot be
used with the software RVS-
COM.
36
appendix.fm5
Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1
Cause
Windows is not respecting the
AT Hayes conditions.
Technically specified time de-
lays that are not supported by
the modem's driver software.
Xmodem is operating in half-du-
plex mode. After every data
package, the transmitting page
waits for acknowledgement.
The 20-30 ms signal delay per
data block on the DECT inter-
face significantly reduces the
transmission speed.
Data transmission is switched
during transmission. AT Hayes
commands are not used for
this.
Cause
PABX configuration is not com-
patible with AT Hayes .
In the case of the system, the
baud rate is switched with an in-
ternal command set that is not
compatible with AT Hayes.
----------------------------
No appropriate modem profile
is available.
Incorrect protocol set.
The initialisation string is incor-
rect.
Commands that are not com-
patible with Hayes are trans-
ferred with the connection.
Solution
None
None
Use another transmission proto-
col, e.g. Zmodem.
None
Solution
Configure Gigaset M101 Data in
direct mode (e.g with
9600,8,N,1).
None
Configure the modem with a di-
rectly connected serial cable.
Tests have shown that an oper-
ative X.75 connection is set up
with the modem profile "ISDN
ELSA TLV34 X.75 64,000".
Set Gigaset M101 Data to 300
bps direct connection. Data
flow setting: without.
The character "/" must be re-
placed by a "~".
Set the Gigaset M101 Data to
115,000 bps direct connection,
see "PC - PC direct cable con-
nection: via RS232/V.24 inter-
face" on page 25