1784-PCIC and -PCICS Drivers
The drivers for the 1784-PCIC and -PCICS are included with either:
• Rockwell Software's RSLinx 2.2 Service Pack 2
Or the combination of:
• Rockwell Software's RSLinx 2.2 Service Pack 1 and
• Rockwell Automation's SoftLogix 5800 6.00
Rockwell Software's RSNetWorx for ControlNet 2.25 is required to configure a
ControlNet network containing the 1784-PCICS.
Refer to online Help in RSLinx for information on how to configure the driver for
the 1784-PCIC/PCICS card. For more information about RSLinx, visit
http://www.software.rockwell.com. See page 4 for additional technical support
information.
The 1784-PCIC and -PCICS cards require one of these operating systems:
• Windows NT 4.0, SP3
• Windows 98
• Windows 2000
Interpret the Status Indicators on the 1784-PCIC and -PCICS
The status indicators on the card give you information about the card and the
network when you're connected via the BNC connectors. Table B outlines the
states and explains what each state means to you and the action you should take, if
any, to correct that state.
ControlNet status interpretation
• steady - indicator is on continuously in the defined state.
• alternating - the two indicators alternate between the two defined
states at the same time (applies to both indicators viewed together).
The two indicators are always in opposite states, out of phase.
• flashing - the indicator alternates between the two defined states
(applies to each indicator viewed independent of the other). If both
indicators flash, they must flash together, in phase.
IMPORTANT
When you connect the module to a ControlNet network using
the network access port (NAP) only, the LEDs are meaningless.
ControlNet PCI Communication Interface Card
Publication 1784-IN003A-EN-P - October 2000
13