NOTE ABOUT EVAPORATIVE COOLERS

For this cooler to effectively cool
a whole house there must be open
windows or doors in each room
where cooling is desired.
NOTE: Evaporative coolers
NOTE: Evaporative coolers
Water bleed or purge:
Evaporative Coolers require a continuous supply of water
to keep the media saturated for maximum cooling. Water
pumped into the cooler must be removed from the unit to
ensure mineral and bacteria build-up do not occur. This can
occur with a gravity-fed steady bleed off stream or a timed
purge system via a pump. A purge pump kit (MCP44-PPK)
is available at www.championcooler.com or at 800.643.8341
to order. See pages 8 and 9 for more details on purge pump
operation.

FEATURES OF THE MASTERCOOL

FAN HOUSING
WITH REMOVABLE
FASCIA
FAN MOTOR
This cooler's housing and frame are made of heavy-duty
Ultra-Violet resistant plastic to provide a light weight, easily in-
stallable cooler. The unit is constructed in two basic sections
to facilitate quick installation into traditional sash windows or
slider windows.
The high-ef ciency rigid media offers superior cooling over
other types of evaporative coolers.
EXHAUST
EXHAUST
Door or window should
be open 4 to 6 inches
WILL NOT
WILL NOT
work in a Closed Room
work in a Closed Room
®

MCP SERIES WINDOW COOLER

FLOAT
WATER PUMP
Ventilation:
Unlike traditional air conditioners, evaporative coolers require
an open ventilation system, not a closed system. Both a fresh
air source and an exhaust opening are required to provide
correct air ow. Typically, a partially opened window or door in
each room where cooling is desired will create correct air ow
for optimum effectiveness of an evaporative cooler. Alternately,
attic ventilation ducts such as UP-DUX
provide sufficient air movement without requiring open windows.
NOTE: For best results, open windows/doors should
not be on the windward side on the house.
CAUTION: Water expelled from the cooler must be
routed away from any areas that could do damage to
foundations or other vulnerable areas.
NOTE: Drawings in this manual are for illustrative
purposes only and may re ect slight differences
depending on design level and con guration.
WATER DISTRIBUTION TRAY
NOTE: Before installing
unit, take a moment to
record the serial number
and write it on the manual
cover in the space pro-
vided.
3
®
can be installed to
EXTERIOR PORTION
MEDIA GUARD
SERIAL NUMBER
ON RIGHT HAND
SIDE OF UNIT.