Preventative Maintenance; General Cleaning - Hamilton Beach SmartServe MIC2000 Service Manual

Drink mixers
Table of Contents

Advertisement

SmartServe™ Drink Mixers Service Manual

Preventative Maintenance

To keep the machine operating properly, it is essential that the machine is cleaned regularly.
Whenever service is performed on the machine, a visual inspection of the components should
be performed to ensure optimal operating conditions.

General Cleaning

The shield will need to be cleaned depending on the application and how many cycles are
completed in a given period.
1.
Clean SmartServe™ using a cleaning solution of hot water (less than 115°F/46°C) and
a nonsudsing detergent according to the package directions.
2.
Turn ON (I) by pressing the power switch under the control panel on the right side.
3.
Remove cup holder.
NOTE: MIC models do not require daily cup holder removal.
4.
Press MENU and select "LOWER SHIELD." Press START.
5.
Turn power OFF (O).
6.
Remove the two thumbscrews from the door assembly and pull off the door assembly.
7.
Push the tab on the front of the cup guard assembly while turning the splash shield to
the left. Let splash shield rest in the wash chamber.
8.
Lift the cup guard assembly upward approximately 3" to allow room to remove the
splash shield.
9.
Wipe the wash chamber, cup lid, and upper part of cup guard assembly with a soft cloth,
bottle brush, or sponge dampened with the cleaning solution.
10. Immerse cup holder, door assembly, and splash shield in cleaning solution and wipe
with a soft cloth or sponge.
NOTE: PARTS ARE NOT DISHWASHER-SAFE.
11. Rinse cup holder, door assembly, and splash shield in clean water; allow to dry.
12. Reassemble the cup holder, splash shield, and door assembly.
13. Turn power ON (I) and allow the machine to return to its HOME position; press the
FLUSH button to flush the water lines.
14. Following the flush cycle, insert a cup filled with cleaning solution and run any pre-
programmed cycle. DO NOT OPEN DOOR WHILE CYCLE IS IN PROGRESS!
15. When cycle is finished, open the door, remove the cup, and pour the solution into the
wash chamber. Close the door. The unit will automatically run through a rinse cycle.
16. Follow sanitizing instructions.
Preventative Maintenance
CAUTION
Blades are sharp.
Page 7 of 92