Siemens REV13 Series Instruction Manual

Siemens REV13 Series Instruction Manual

24-hour room temperature controller
Hide thumbs Also See for REV13 Series:

Advertisement

s
Use
CE1N2201en
2018-11-07
24-hour
room temperature controller
Heating applications
·
Mains-independent, battery-operated room temperature controller featuring
user-friendly operation, easy-to-read display and large numbers
·
Self-learning two-position controller with PID response (patented)
·
Operating mode selection:
- Automatic mode with two heating phases
- Automatic mode with one heating phase
- Continuous comfort mode
- Continuous energy saving mode
- Frost protection
·
Automatic modes with time switch program
·
Heating zone control
Room temperature control in:
· Single-family and vacation homes.
· Apartments and offices.
· Individual rooms and professional office facilities.
· Commercially used spaces.
Control for the following equipment:
· Magnetic valves of an instantaneous water heater.
· Magnetic valves of an atmospheric gas burner.
· Forced draught gas and oil burners.
· Electrothermal actuators.
· Circulating pumps in heating systems.
· Electric direct heating.
· Fans of electric storage heaters.
· Zone valves (normally open and normally closed).
2
201
REV13..
Building Technologies
HVAC Products

Advertisement

loading

Summary of Contents for Siemens REV13 Series

  • Page 1 24-hour REV13.. room temperature controller Heating applications · Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large numbers · Self-learning two-position controller with PID response (patented) · Operating mode selection: - Automatic mode with two heating phases - Automatic mode with one heating phase - Continuous comfort mode - Continuous energy saving mode...
  • Page 2 The easily accessible battery compartment allows for easy exchange of two 1.5 V alkaline batteries, type AAA. The base with terminal block provides lots of space to connect the wires. Display and operating elements 2 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 3 The unit first displays queued error messages followed by important information (e.g. time switch programs, etc.). Plus button Increase values, set time, or make a selection. 3 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 4 Comfort temperature for the automatic mode time switches A and B. Energy saving temperature for the automatic mode time switches A and B. Temperature setpoint at active remote control. Slider position RUN allows for closing the cover. 4 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 5 Setting range for all setpoints with setpoint limitation 16…35 °C. Factory setting Factory settings: Heating 20 °C 16 °C 8 °C 12 °C Factory settings: Switching times 06:00 08:00 17:00 22:00 07:00 23:00 5 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 6 After you change one or several DIP switch positions, you must press the DIP switch reset button to reset the DIP switch. Otherwise, the previous setting remains active! Factory setting: All DIP switches to 6 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies...
  • Page 7 RUN position during these 10 minutes. Siemens recommends to set the desired settings upon startup, install the REV..DC in the desired location, and not carry out any actions on the REV..DC for the next 10 minutes.
  • Page 8 · It is possible that in heating mode the room temperature is higher than the set temperature setpoint. e) Set the temperature setpoint for operating mode “Continuous comfort mode“ to the desired value. f) Select the desired operating mode. 8 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 9 · You can change the control characteristics using the DIP switch on the rear of the unit. · Set any thermostatic radiator valves to their fully open position, if present in the reference room. 9 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 10 Do not mixed new batteries with used batteries. · Store, transport, and dispose of the batteries in accordance with local regulations, guidelines, and laws. Also observe information from the battery manufacturer. 10 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 11 0.24 kg Color Housing RAL9003 signal white Base RAL7038 gray Size Housing with base 94 x 130 x 30 mm *) The documents can be downloaded from http://siemens.com/bt/download 11 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 12 Thermal reset limit thermostat 3-port valve with manual adjustment Manual reset safety limit thermostat Magnetic valve Circulating pump Three-port valve with actuator REV13.. room temperature controller Y4 Two-port valve with actuator 12 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 13 Dimensions 13 / 14 Siemens Room temperature controller REV13.. CE1N2201en Building Technologies 2018-11-07...
  • Page 14 Issued by © Siemens Switzerland Ltd, 2008 - 2018 Siemens Switzerland Ltd. Technical specifications and availability subject to change without notice. Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies 14 / 14 Siemens Room temperature controller REV13..